Page 12
VS-616/676 Series Option Instruction Manual: Isolated Analog Monitor Card AO-12B2
Note:
Refer to “OUTPUT SIGNAL LEVEL SETTING” for 100% output signal level in output content.
Table 8: Programming Settings With VS-616H3
Terminal
Program
Constant No.
Set
Value
Output Contents
Output
Accuracy
TB1-1
Channel 1
bn-15
1
Frequency reference:
Max. frequency/100%
1.0%
2
Output frequency:
Max. frequency/100%
3.0%
3
Output current
Rated current/100%
1.5%
4
Output voltage reference:
input voltage/100%
1.5%
5
DC voltage (V
PN
)
400v/100% (200V class)
TB1-2
Channel 2
bn-17
6
Output Power
(+ indication):
Rated power (kW) 100%
10%
17
Speed feedback (PG,G):
Max. frequency/100%
18
Compensated
frequency (PG,TG):
Max. frequency/100%
19
Voltage feedback (AVR):
Input voltage/100%
20
Compensated voltage (AVR):
Input voltage/100%
21
Momentary reduced value:
Max. frequency/100%