background image

Home

 Position 1

End

 End

BS

 Backspace

up

 

ã

dn

 

ä

lt

 

á

rt

 

â

pgup

 Page 

ã

pgdn

 Page 

ä

ins

 Insert

del

 Delete

Tab

 Tabulator

Shift

Caps/Lock

The software keyboard allows you to enter key entries without connecting an external

keyboard. As soon as an entry is required the software keyboard is automatically shown.

Hide Input Panel

 hides the keyboard again.

As many components of the 

Control Panel

 conform with the 

system control

 of Windows

Ò

,

most of the description is not necessary. The description of the control panel components

relevant for operating the Touch Panel can be found in the following:

n

Set display

Via 

‘Start

 

è

 Settings

 

è

 Control Panel

 

è

 Display’

 the dialog windows for the display

properties opens. Here you may change the settings for the monitor options. For

example you may adjust the brightness and contrast via the register 

Settings.

n

Calibrate touch screen

If the touch screen does not always react to a double click or not precisely recognize

the position of an entry, you can call the dialog 

Stylus

 via 

‘Start

 

è

 Settings

è

 Control Panel’

. In the register 

Double-Tap

 you can use the grid pattern to preset a

double click velocity and test this on the symbol below. Click [OK] to accept the value.

The calibration of the touch screen is completed via the register 

Calibration

 by fol-

lowing the instructions.

Meaning

Hide keyboard

System setting (Control

Panel)

VIPA HMI

Deployment under Windows CE 6.0 Core

Operating system Windows

Ò

 Embedded CE 6.0 Core > Structure

HB160 | TP-ECO | 62K-NHC0 | en | 17-09

 

35

Содержание VIPA TP-ECO

Страница 1: ...TP ECO 62K NHC0 Manual HB160 TP ECO 62K NHC0 en 17 09 VIPA HMI Touch Panel TP610LC www vipa com en service support manual...

Страница 2: ...62K NHC0_000_TP610LC 4 EN 2017 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Страница 3: ...ger 28 3 5 Connection to a PLC system 31 3 6 Operating system Windows Embedded CE 6 0 Core 31 3 6 1 General 31 3 6 2 Structure 33 3 7 Integrated Server 37 3 7 1 General 37 3 7 2 ftp server 38 3 7 3 VN...

Страница 4: ...he EMC equitable assembly of installations 65 5 2 EMC equitable assembly 68 5 3 EMC equitable cabling 69 5 4 Special precautions providing high noise immunity 72 5 5 Checklist for the EMC compliant in...

Страница 5: ...ective purchase contract Hereby VIPA GmbH declares that the products and systems are in compliance with the essential requirements and other relevant provisions Conformity is indicated by the CE marki...

Страница 6: ...NHC0 DH 01 Windows CE 6 0 Core TP 610LC 62K NHC0 CB 01 Windows CE 6 0 Prof The manual is targeted at users who have a background in automation technology The manual consists of chapters Every chapter...

Страница 7: ...onnel in the n project design department n installation department n commissioning n operation CAUTION The following conditions must be met before using or commis sioning the components described in t...

Страница 8: ...regulations for handling the respective equipment can prevent failures of electrostatic sensitive modules Modules must be shipped in the original packing material When you are conducting measurements...

Страница 9: ...PROFIBUS DP interface optional n Robust aluminium case n Display resolution 1024 x 768 768 x 1024 n Battery backed clock n Resistive analog touch screen n Easy mounting via 10 mounting clips n Protec...

Страница 10: ...4 RJ45 jack for Ethernet communication LAN 2 5 RS232 interface COM 1 6 RS232 RS422 RS485 interface COM 2 7 MPI PROFIBUS DP interface COM 3 optional 8 Slot for DC 24V voltage supply 9 Display with tou...

Страница 11: ...hernet interfaces cannot be used as a Switch 1 RS232 interface COM 1 2 RS232 RS422 RS485 interface COM 2 3 MPI PROFIBUS DP interface COM 3 optional 4 Slot for DC 24V voltage supply Please make sure th...

Страница 12: ...2 3 2 Interfaces VIPA HMI Hardware description Structure Interfaces HB160 TP ECO 62K NHC0 en 17 09 12...

Страница 13: ...25 pin SubD female RS232 RS422 RS485 inter face VIPA HMI Hardware description Structure Interfaces HB160 TP ECO 62K NHC0 en 17 09 13...

Страница 14: ...these two Ethernet interfaces cannot be used as a Switch Using the Host USB A interface USB mouse keyboard stick or USB hard discs can be connected The Touch Panel has got an integrated power supply...

Страница 15: ...f Windows CE this memory is listed as Flashdisk at My Device The connection of USB sticks and USB drives by use of the Host USB A interface is supported by the Touch Panel After connection the storage...

Страница 16: ...e degrees of protection are only guaranteed when the following is observed Material thickness at the mounting cut out 2 5 6mm The deviation from the plane for the panel cut out is 0 5mm Permissible su...

Страница 17: ...voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14 20 6...

Страница 18: ...lses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data 2 6 1 62K NHC0 DH Order no 6...

Страница 19: ...or Sub D 9 pin male Serial COM2 RS232 RS422 RS485 COM2 connector Sub D 25 pin female Number of USB A interfaces 1 USB A connector USB A host Number of USB B interfaces USB B connector Number of ethern...

Страница 20: ...m Minimum 2 5 mm Maximum front panel thickness 6 mm Weight 3350 g Environmental conditions Operating temperature 0 C to 50 C Storage temperature 20 C to 60 C Certifications UL certification yes KC cer...

Страница 21: ...4 h Accuracy max deviation per day 2 s Operating controls Touchscreen resistive Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUS DP optional MPI PROFIBUS DP connector Serial CO...

Страница 22: ...ion type Material aluminum galvanized steel Mounting mounting clips Protect type front side IP 65 Protect type back side IP 20 Dimensions Front panel 325 mm x 263 mm x 6 mm Rear panel 310 mm x 248 mm...

Страница 23: ...ation of the panel 4 mounting clips and a small hexagon socket key are required 1 Push the operator panel 3 from the front side into the front panel cutting 1 until it touches the panel with the seal...

Страница 24: ...the corresponding ESD packaging 1 Remove the cover plate of the COM3 port by removing the screws and pulling the plate 2 For installation insert the interface module into the opening Push the interfa...

Страница 25: ...lation the interface module is automatically recognized and can be configured 1 Remove the screws 2 Push the holding plate from the lugs Use a screwdriver by inserting it gently between the housing an...

Страница 26: ...on as the Touch Panel is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following start screen appears n There is a button on the...

Страница 27: ...elect image is not suited for your panel an error massage appears If the image is suited for your panel in the following message the current installed image version and the new selected image version...

Страница 28: ...Autostart you can select the automatic startup of the VNC server and the Movicon TCP upload server With back you can return to the selection menu The Startup Manager will be closed by Exit and the sys...

Страница 29: ...els navigate to your Panel and download the zip file to your PC 4 Unzip the zip file and copy the file to the root directory of your SD card 5 Switch on the panel install the SD card and select via St...

Страница 30: ...wait a moment After successful execution the following completion screen appears 9 Confirm this window with OK remove the SD card and re start the panel The panel should start with the Startup Manager...

Страница 31: ...icates with the according PLC and reacts to the application courses in the PLC according to the configured processes Via dialogues configured before process values may be monitored graphically altered...

Страница 32: ...k on an object opens res executes this n Drag By tapping on an object and then dragging you may move the object on the screen If no object is selected a frame is created by the dragging that selects t...

Страница 33: ...like e g applications system settings file browser etc 2 Open applications For every open application a button is to be found in the task bar There is no button for minimizing The switch between the a...

Страница 34: ...e implemented At pushed Shift key At pushed a key Please note that can exclusively be entered via the software key board Keyboard At pushed Shift key Software keyboard Keyboard Large KB VIPA HMI Deplo...

Страница 35: ...ialog windows for the display properties opens Here you may change the settings for the monitor options For example you may adjust the brightness and contrast via the register Settings n Calibrate tou...

Страница 36: ...pyright The register Device Name allows you to change the device name that is e g shown during Ethernet communication n Set the back lighting Via Start Settings Control Panel Power Properties you may...

Страница 37: ...client is an application that uses the service of a server within a network For example a web browser is a client because at every call of a website it sends a request to a web server and receives an...

Страница 38: ...start the Internet Explorer The settings are saved Below is explained how to establish of a ftp connection between a Windows based PC with Windows Explorer as ftp client and your Touch Panel 1 Connect...

Страница 39: ...server is on delivery deactivated Due to software reasons VIPA does not support the VNC server function With Autostart you can select the automatic startup of the VNC server via the Startup Manager Th...

Страница 40: ...Touch Panel allows you to access shared resources in a Microsoft network like drives and printer Here you may assign existing public directories or printer in the network to local directories or print...

Страница 41: ...tserver archive Username guest Input net use data testserver archiv user guest The connected network drive is then available via network data at the Touch Panel The configuration of a network printer...

Страница 42: ...a net use local_name d Example net use data d deletes the network connection to the drive archive of test server Terminate network con nections VIPA HMI Deployment under Windows CE 6 0 Core Access to...

Страница 43: ...ation of the panel 4 mounting clips and a small hexagon socket key are required 1 Push the operator panel 3 from the front side into the front panel cutting 1 until it touches the panel with the seal...

Страница 44: ...the corresponding ESD packaging 1 Remove the cover plate of the COM3 port by removing the screws and pulling the plate 2 For installation insert the interface module into the opening Push the interfa...

Страница 45: ...lation the interface module is automatically recognized and can be configured 1 Remove the screws 2 Push the holding plate from the lugs Use a screwdriver by inserting it gently between the housing an...

Страница 46: ...oon as the Touch Panel is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following start screen appears n There is a button on th...

Страница 47: ...nd connected storage media These images will be listed with create data and version number Choose your new image If the select image is not suited for your panel an error massage appears If the image...

Страница 48: ...y using the buttons and 5 seconds are default n Via Rotation the orientation of the panel can be changed Via Program start with you can add programmes which have to start automatically 1 Select start...

Страница 49: ...rtup Manager 4 4 Installation Movicon and Startup Manager After an image update it is necessary to re install Movicon and Startup Manager The cur rent data can be found in the service area of www vipa...

Страница 50: ...After start up the following window appears 7 Click Make All the necessary files are copied and the registry is accordingly adjusted The progress is displayed in a new window VIPA HMI Deployment under...

Страница 51: ...screen appears 9 Confirm this window with OK remove the SD card and re start the panel The panel should start with the Startup Manager after the restart VIPA HMI Deployment under Windows CE 6 0 Prof...

Страница 52: ...icates with the according PLC and reacts to the application courses in the PLC according to the configured processes Via dialogues configured before process values may be monitored graphically altered...

Страница 53: ...area at the screen twice A double click on an object opens res executes this n Drag By tapping on an object and then dragging you may move the object on the screen If no object is selected a frame is...

Страница 54: ...components of your Touch Panel like e g applications system settings file browser etc 2 Open applications For every open application a button is to be found in the task bar There is no button for min...

Страница 55: ...ou to select one of the available software keyboards At the moment the following standard keyboards are implemented At pushed Shift key At pushed a key Please note that can exclusively be entered via...

Страница 56: ...rd allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides the keyboard again Large...

Страница 57: ...ial up Connections The default setting is address assignment via DHCP Please consider with the manual assignment of IP addresses that these are not identical for both interfaces If you accidentally ha...

Страница 58: ...iption of the server A client is an application that uses the service of a server within a network For example a web browser is a client because at every call of a website it sends a request to a web...

Страница 59: ...start the Internet Explorer The settings are saved Below is explained how to establish of a ftp connection between a Windows based PC with Windows Explorer as ftp client and your Touch Panel 1 Connect...

Страница 60: ...ter the following into the address bar IP address webadmin 2 Enter the following into the authentification n User name wince n Password vipatp 4 7 4 Telnet server Telnet is a text based client server...

Страница 61: ...Panel content for remote control Operation is performed via PC keyboard and mouse Condition for the VNC communication is that the VNC server is started on the Touch Panel and a VNC client on the PC Y...

Страница 62: ...start the VNC client vncviewer exe on your PC 4 Click on Options and deactivate the field Emulate 3 Buttons like shown at Mouse 5 Enter the IP address of the Touch Panel at VNC server Click on OK and...

Страница 63: ...ork PC The connection of a local name at the Touch Panel with a shared drive of the network PC happens with the following approach 1 Enter the following in the command prompt net use local_name networ...

Страница 64: ...ectory using dir network printer The listing command for all network connections of your Touch Panel is net use You may terminate already assigned network resources via net use local_name d Example ne...

Страница 65: ...erent ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead free...

Страница 66: ...ie n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following ba...

Страница 67: ...ecial EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrical...

Страница 68: ...age even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts hav...

Страница 69: ...groups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installed...

Страница 70: ...e equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is connecte...

Страница 71: ...e cover Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and to...

Страница 72: ...diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutral...

Страница 73: ...een grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunche...

Отзывы: