1. RATINGS AND SPECIFICATIONS
1. 1 RATINGS AND SPECIFICATIONS OF R SERIES AC SERVOMOTORS (FOR 200 V)
(1)
R a t i n g s
Time R a t i n g : C o n t i n u o u s
I n s u l a t i o n : C l a s s B
Isolation V o l t a g e : 1 0 0 0 V A C , o n e m i n u t e
I n s u l a t i o n R e s i s t a n c e : 5 0 0 V D C , 1 0 MO o r m o r e
E n c l o s u r e : T o t a l l y - e n c l o s e d , s e l f - c o o l e d
A m b i e n t Te m p e r a t u r e : 0 t o + 4 0 ° C
S t o r a g e Te m p e r a t u r e - 2 0 t o +60°C
Motor Type USAREM-
Item
A5A 2
-01A 2
-D2A 2
-03A 2
-05A 2
-07A , 2
Rated Output*
W
(HP)
50
(0 07)
100
(0 13)
200
(0 27)
300
(0 40)
500
(0 67)
700
(0 93)
Rated Torque*
N
•
in
(oz•in)
0 159
(22 5)
0 318
(45)
0 637
(90)
0 955
(135)
1 59
(225)
2 23
(316)
Continuous Max Torque* N • r n
(oz• in)
0 182
(25 9)
0 367
(51 8)
0 733
(103 5)
1 1
(155 3)
1 82
(258.8)
2 56
(363 0)
Instantaneous Max Torque* N • r n
(oz• in)
0 476
(675)
0 955
(135)
1 91
(270)
2 86
(405)
4 76
(675)
6 68
(948)
Rated Current*
A
0 99
1 36
2 75
3 70
5 29
5 29
Rated Speed*
r
/
m
i
n
3000
Max Speed*
r
/
m
i
n
4500
Torque Constant
N
•
m/A
(oz• in/A)
0 17
(24 0)
0 247
(35 0)
0 243
(34 4)
0 271
(38 5)
0 319
(45 3)
0 457
(60 4)
Inertia
kg • m2 X10-6
J
(oz- I n -s2 X 1 0 - 3 )
7 64
(1 08)
12 5
(1 78)
50 7
(7 18)
76 6
(10 9)
272
(38 6)
372
(52 8)
Power Rating*
k
W
/
s
3.30
8.09
8.01
11 9
9 26
13 3
Inertia Time Constant
m
s
5 0
3 7
3.6
3 1
3.6
3 4
Inductive Time Constant m s
1 2
1 5
3 8
4 2
8 7
9.9
A m b i e n t H u m i d i t y : 20% t o 80% ( n o n - c o n d e n s i n g )
V i b r a t i o n : 1 5 p m o r b e l o w
Finish i n M u n s e l l N o t a t i o n : N 1 . 5
E x c i t a t i o n : P e r m a n e n t m a g n e t
M o u n t i n g : F l a n g e m o u n t e d
D r i v e M e t h o d : D i r e c t d r i v e
Table 1.1 Ratings and Specifications of R Series
AC SERVOMOTORS (For 200V)
* Values when SERVOMOTOR is combined with SERVOPACK and the armature winding temperature s 75°C
Other values at 20°C S h o w n are normal (TYP) values above
Notes
1 i : : ] in type designation is determined by output pulses (pulses/rev) of optical encoder as follows
• Standard E (1500 pulses/rev)
• Optional F (1000 pulses/rev)
2 T h e power supply unit for brake
• Input 200 VAC Output 90 VDC (DP8401002 1)
For details, see Par 8 3 (2) on page 38
3 T h e table above shows the data when an aluminum plate (heat sink) 25(1mm x 250 mm x 6 mm
(9 84 in x 9 84 in x 0 24 in) i s mounted as a cooling agent
1