2.2Setting Parameters According to Host Controller
— 2-33 —
Selecting Torque Control
Use the following memory switch to select level 3 (torque control).
Cn-01 Bit A
Control Mode Selection
Factory
Setting: 0
For Speed/Torque Control
Cn-01 Bit B
Control Mode Selection
Factory
Setting: 0
For Speed/Torque Control
A motor torque reference value is externally input into the Servopack to control torque.
Examples of Use:
Tension control
Pressure control
Cn-01
Setting
Control Mode
Bit B Bit A
Control Mode
Torque Control
This is a dedicated torque control mode.
D
A torque reference is input from T-REF.
D
/P-CON is not used.
Torque
reference
Servopack
1
0
D
Speed reference input V-REF cannot be
used.
D
Parameter Cn-14 can be used for
maximum speed control.
Example of Use:
Tension control
Tension
Servo-
pack
Servomotor
1
1
Not used (do not set)
0
0
Speed control (standard setting)
0
1
Zero-clamp speed control
Input Signals
The following input signals perform torque control.
CN1-12
CN1-13
SG
V-REF/T-REF
Torque reference input
(Analog voltage input)
Speed reference input
(Analog voltage input)
Servopack
Speed/ torque
reference
: Twisted-pair cable.
2