3.1Basic Operations
— 3-7 —
3.1.5 Operation in Parameter Setting Mode
Parameters are used to select and adjust various functions. Two types of parameter are used
as follows:
Constant Settings (Cn-03 to Cn-2C)
Memory Switches (Cn-01, Cn-02)
The setting method is different for each type. The constant settings (Cn-03 to Cn-2C) allow
setting of a constant within a fixed range. The memory switches (Cn-01, Cn-02) allow the re-
quired functions to be selected. Refer to
Appendix C List of Parameter Settings
.
Changing the Constant Settings (Cn-03 to Cn-2C)
The constant settings (Cn-03 to Cn-2C) allow setting of a constant within a fixed range. Check
the permitted range of the constant in
Appendix C List of Parameter Settings
, before chang-
ing the data. The following example shows how to change user setting Cn-15 from 100 to 85.
1) Press
DSPL
SET
to select the parameter set-
ting mode.
2) Select the parameter number to set.
Press the
and
keys to select the
digit.
Press the
and
keys to change the
value.
3) Press
DATA
ENTER
to display the current data for
the parameter selected at step 2.
4) Set the required data.
Press the
and
keys to select the
digit.
Press the
and
keys to change the
value.
5) Press
DATA
ENTER
to store the data.
6) Press
DATA
ENTER
once more to display the pa-
rameter number again.
7) Repeat steps 2 to 6 as often as required.
3
Setting
Mode
The selected
digit flashes.
Parameter
Number
Data
The selected
digit flashes.
The stored
data flashes.
Parameter
Number
Data
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com