STEP 4: PV Output Circuit Wiring Terminations in the Re-Combiner
The PV Output Circuit conductors terminate on tabs extending from the DC switch. The
tabs are factory-supplied with dual studs to maintain conductor alignment. Figure 5.3
illustrates the terminations and the sections below identify the relevant specifications.
Note that users must supply the Crimp Lug and Fasteners as defined.
PV Output Circuit Conductors Terminations
Lugs
Compression lugs are NOT provided with the Re-Combiner. The lugs must
conform to the specifications given in the table below:
Conductors
Conductor Termination
Single and Dual Conductor Terminations
Lug Type
Plating &
Material
Max. Tongue
Width
Hole Size
Temp
Rating
Two-Hole
Tin Plated Cu
1.95 in
for M8 stud
90C
Max distance from hole center to end of lug
14 mm
Max Allowable Conductor Size
Cu or Alum, 90C temp rating
1 or 2 cond at 500 kcmil
1 cond at 750 kcmil
Fasteners
(Supplied)
A: 8mm flanged nut, SS
Torque: 90 in-lb (10 Nm)
Dual Conductors
Crimp Lugs
Single
Conductor Crimp
Lug
A
Positive polarity conductors (red wires in Fig 5.3) connect to a fuse.
Confirm polarity and fuse connection for positive conductors.
A