PVI 23TL, 28TL Installation and Operation Manual (Rev J)
DOCR-070365-J
Page
53
of
66
Protection
4. GridF.OutLim
Grid voltage
frequency is
abnormal
1. Grid frequency is
out of range.
1. Observe for 10min and
see whether the alarm is
cleared automatically.
2. Verify grid frequency is
within range.
3. Verify proper AC wiring.
4. If error does not clear,
Contact Solectria
Customer Service.
2. Loose AC
connections.
Protection
5- PV1 (2)
VoltOver
DC input
voltage exceeds
the specified
value
1. DC over-voltage.
1. Observe for 30min and
see whether the alarm is
cleared automatically.
2. Verify DC open circuit
input voltage is within
specified range.
3. Switch off the inverter’s
internal disconnects.
Switch the Inverter back
on.
4. If error does not clear,
contact Solectria
Customer Service.
Protection
6. PV1 (2)
Reverse
DC inputs
connected with
incorrect
polarities
1. PV positive pole
and negative pole
are connected in
reverse.
1. Verify DC voltage
polarity is correct on all
inputs.
2. If error does not clear,
contact Solectria
Customer Service.
Protection
7. GFCI.Err
DC leakage
current is above
recommended
value
1. Excessive parasitic
capacitance on PV
module due to
insulation failure.
1. Observe for 10min and
see whether the alarm is
cleared automatically.
2. Contact System installer
to check installation for
possible Ground Fault.
3. If error does not clear,
contact Solectria
Customer Service.
2. Abnormal
grounding
conditions.
Protection
8. IsolationErr
DC insulation
impedance to
ground
1. Insulation to
ground is below
recommended value.
Contact System installer
to check installation for
possible Ground Fault.