9 Troubleshooting
EN 42
YASKAWA ELECTRIC
TOBP C730600 59A V1000 Option Modbus TCP/IP Installation Manual
n
Minor Faults and Alarms
u
Option Error Codes
n
Option Fault Monitors U6-98 and U6-99
The option can declare error/warning conditions via drive monitor parameters on the drive
digital operator as shown in
Table 15
.
Table 15 Option Fault Monitor Descriptions
LED Operator Display
Fault Name
oFA04
Option Card Fault
Option flash write mode.
Cause
Possible Solution
Option hardware fault
Replace the option.
LED Operator Display
Fault Name
to
oFA30 to
oFA43
Option Card Fault
Communication ID error.
Cause
Possible Solution
Option hardware fault
Replace the option.
LED Operator Display
Minor Fault Name
CALL
Serial Communication Transmission Error
Communication is not established.
Cause
Possible Solution
Minor Fault
(H2-
= 10)
Communication wiring is
faulty, there is a short
circuit, or improper
connection
Check for wiring errors:
• Correct the wiring
• Remove ground shorts and reconnect loose wires
YES
Programming error on the
master side
Check communications at start-up and correct programming errors.
Communication circuitry
is damaged.
• Perform a self-diagnostics check
• Replace the drive if the fault continues to occur
Fault Condition
Fault Declared
Status Value
(U6-98/U6-99)
Description
No Fault
n/a
0
No faults