2 Replacement GA500 Drive Selection
YASKAWA America, Inc.
PL.GA500.01 YASKAWA AC Drive - V1000 to GA500 Transition Guide
5
2
Replacement GA500 Drive Selection
through
provide a model to model cross reference. Select the GA500 model that corresponds to your
V1000 model.
Increasing the Carrier Frequency parameter C6-02 from the factory default setting may require derating of the drive
capacity.
Refer to Carrier Frequency - C6-02 [Carrier Frequency Selection] on page 40
to understand the effect of
changing parameter C6-02 on your new replacement drive.
Note:
Normal Duty overload tolerance.
• V1000 120% of rated normal duty current for 60 seconds.
• GA500 110% of rated normal duty current for 60 seconds.
Table 1 Single-Phase 240 V Models
Table 2 Three-Phase 240 V Models
V1000 Model
CIMR-VU
Rated Output
Heavy Duty (HD)
Amps
Rated Output
Normal Duty (ND)
Amps
GA500 Catalog
Code
GA50U
Rated Output
Heavy Duty (HD)
Amps
Rated Output
Normal Duty (ND)
Amps
BA0001
0.8
1.2
B001
0.8
1.2
BA0002
1.6
1.9
B002
1.6
1.9
BA0004
3.0
3.3
B004
3.0
3.5
BA0006
5.0
6.0
B006
5.0
6.0
BA0010
8.0
9.6
B010
8.0
9.6
BA0012
11.0
12.0
B012
11.0
12.2
BA0018
17.5
-
B018
17.6
-
V1000 Model
CIMR-VU
Rated Output
Heavy Duty (HD)
Amps
Rated Output
Normal Duty (ND)
Amps
GA500 Catalog
Code
GA50U
Rated Output
Heavy Duty (HD)
Amps
Rated Output
Normal Duty (ND)
Amps
2A0001
0.8
1.2
2001
0.8
1.2
2A0002
1.6
1.9
2002
1.6
1.9
2A0004
3.0
3.5
2004
3.0
3.5
2A0006
5.0
6.0
2006
5.0
6.0
2A0010
8.0
9.6
2010
8.0
9.6
2A0012
11.0
12.0
2012
11.0
12.2
2A0020
17.5
19.6
2021
17.6
21.0
2A0030
25.0
30.0
2030
25.0
30.0
2A0040
33.0
40.0
2042
33.0
42.0
2A0056
47.0
56.0
2056
47.0
56.0
2A0069
60.0
69.0
2070
60.0
70.0
-
-
-
2082
75.0
82.0