8 MEASURES TO SATISFY THE EMC DIRECTIVE
E-19
8
MEASURES TO SATISFY THE EMC DIRECTIVE
This section describes the measures required for NS500 Module to conform to EMC Directive
(EN50081-2, EN50082-2, EN61000-6-2).
8.1
Profibus-DP Communication Cable
For Profibus-DP communication (CN6) connector, use the cable for special use.
For max. cable length, refer to
4.2 Precautions on Wiring
.
8.2
Fully Closed Encoder Cable
For fully closed encoder (CN4) connector, use the following connector.
Use the twisted pair shielded cable.
Connector: 54306-2011 (Made by Molex Japan Co., Ltd.)
Connector case: 54331-0201 (Made by Molex Japan Co., Ltd.)
8.3
The Core on the Cable
Attach the core on the cable as shown below:
Cable line and the line position where the core are attached are shown below.
Note: For details on the SERVOPACK core and the line filter, refer to
Σ
-II
series SGDH Instruction Manual (TOB-S800-32).
Model
ESD-SR-25
ESD-SR-250
(RoHS compliance)
Quantity
1
Turn
2
Manufacturer
Tokin Corp.
Cable Name
Mounting Position of Core
Profibus-DP Communication Cable
Near the host controller and SERVOPACK
Fully Closed Encoder Cable
Near the SERVOPACK
Cable
Core