E-10
2.4
Mounting NS500 Module
Mount a NS500 Module on a SGDH SERVOPACK in the following manner. Provide the
screws for connecting ground wire as shown below.
1. Remove the connector cover mounted on CN10 of SERVOPACK.
2. Mount an application module.
Mounting
Method
SERVOPACK Type
Screw
Remarks
Base
mounted
SGDH-A3 to 02BE
SGDH-A3 to 10AE
M3
×
10 round head screws
(with spring washer and plain
washer)
Attachments.
SGDH-15 to 50AE
SGDH-05 to 50DE
M4
×
10 round head screws
(with spring washer and plain
washer)
Attachments.
SGDH-60 to 1EAE
SGDH-60 to 1EDE
M4
×
8 round head screws
(with spring washer and plain
washer)
Use the screw of the front panel.
Rack
mounted
SGDH-A3 to 02BE-R
SGDH-A3 to 50AE-R
SGDH-05 to 50DE-R
M4
×
6 round head screws
(with spring washer and plain
washer)
Attachments.
Note: Make sure that spring washers and
plain washers are used for mounting.
(Otherwise, the screw for connecting
ground wire sticks out from the other
side of the flange, and the SERVOPACK
cannot be mounted properly.)
Duct
ventilated
SGDH-60 to 1EAE-P
SGDH-60 to 1EDE-P
M4
×
8 round head screws
(with spring washer and plain
washer)
Use the screw of the front panel.
MODE/SET
DATA/
CHARGE
POWER
SGDH−
SERVOPACK
YASKAWA
Connector
cover
CN10
SERVOPACK
CN10
L1
L2
1
2
L1C
L2C
B1
B2
U
V
W
YASKAWA SERVOPACK
SGDH−
Ver.
POWER
CHARGE
Connector