background image

n

System properties

Via 

‘Start

 

è

 Settings

 

è

 System and Security

 

è

 System’

 you

receive information about the version of the current Windows

Ò

operating system and the copyright.
Via 

‘System Protection’

 or 

‘Change settings’

 under 

‘Change’

 you

can change the device name that is shown during Ethernet com-

munication for instance.

n

Allow remote access

By default, remote access to the Panel PC is disabled. For

release, open the window 

‘Remote’

 via 

‘Start

 

è

 Control Panel

è

 System and Security

 

è

 System

 

è

 Allow remote access’

,

choose one of the release options and confirm with [OK].

By default, the Panel PC automatically logs in with the user name

VIPA

 and the password 

vipatp

. If the user needs to enter name and

password to use the Panel PC, the procedure is as follow:

1.

Type "cmd" under 

‘Start

 

è

 Run’

.

2.

In the next window type "control userpasswords2".

3.

In the opening dialog window check the box 

‘User must enter a

user name and password to use this computer.’

 and confirm

with [Apply]. You can also change the password in this section

under [Reset Password] at any time.

Disable automatic log-in

VIPA HMI

Deployment Panel PC

Operating system Windows Embedded Standard 7 > Structure

HB160 | PPC | 67K-PNL0 | GB | 16-40

 

35

Содержание PPC010 ES

Страница 1: ...PPC 67K PNL0 Manual HB160 PPC 67K PNL0 GB 16 40 VIPA HMI Panel PC PPC010 ES...

Страница 2: ...67K PNL0_000_PPC010ES 1 GB 2016 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Страница 3: ...ard 26 3 3 Commissioning 27 3 3 1 VIPA Startup Manager 27 3 4 Connection to a PLC system 30 3 5 Operating system Windows Embedded Standard 7 31 3 5 1 General 31 3 5 2 Structure 32 4 BIOS setup 38 4 1...

Страница 4: ...com Every effort has been made to ensure that the informa tion contained in this document was complete and accurate at the time of publishing Nevertheless the authors retain the right to modify the in...

Страница 5: ...er service centre contact VIPA as follows VIPA GmbH Ohmstra e 4 91074 Herzogenaurach Germany Telefax 49 9132 744 1204 EMail documentation vipa de Contact your local VIPA Customer Service Organization...

Страница 6: ...y is possible CAUTION Damages to property is likely if these warnings are not heeded Supplementary information and useful tips 1 3 Safety information The system is constructed and produced for n commu...

Страница 7: ...are modifications to the process control system should only be carried out when the system has been disconnected from power Installation and hardware modifications only by properly trained personnel T...

Страница 8: ...les that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the conse quent implementation of protection devices...

Страница 9: ...T Panel 262K n PCAP multitouch n Display resolution 1280 x 800 800 x 1280 n Intel Atom Processor D2550 Dualcore 1 86GHz 1M L2 Cache n Work memory 2x 204Pin DDR3 SO DIMM Socket 2GB DDR3 n User memory 1...

Страница 10: ...nterface COM 1 6 4x Host USB A interface 7 RJ45 jack for Ethernet communication LAN 2 8 RJ45 jack for Ethernet communication LAN 1 9 3 5mm Audio Line out 10 Power switch pushbutton 11 Slot for CFast s...

Страница 11: ...rface 7 RJ45 jack for Ethernet communication LAN 2 8 RJ45 jack for Ethernet communication LAN 1 9 3 5mm Audio Line out Please make sure that the Panel PC always has to be supplied with external voltag...

Страница 12: ...r switch By pushing the power switch again the sleep mode is switched off 2 3 2 Interfaces The 9 pin male SubD connector may be switched in the BIOS Here also the termination resistor of the RS422 and...

Страница 13: ...1200m at 19 2kbit s n Data transfer rate up to 115 2kbit s RS485 interface n Logical conditions as voltage difference between 2 twisted lines n Serial bus connection half duplex two wire operation n...

Страница 14: ...VIPA HMI Hardware description Structure Interfaces HB160 PPC 67K PNL0 GB 16 40 14...

Страница 15: ...ding DC 24V slot at the back The power supply is protected against inverse polarity and overcurrent 2 3 3 Memory management n 2GB work memory n 16GB SSD user memory n USB storage media using Host USB...

Страница 16: ...SATA_TX1 PC7 GND S3 SATA_TX1 PC8 CFAST_LED1_C S4 GND PC9 CFAST_LED2_C S5 SATA_RX1 PC10 n c S6 SATA_RX1 PC11 n c S7 GND PC12 n c PC1 CFAST_CDI PC13 VCC3 PC2 GND PC14 VCC3 PC3 n c PC15 GND PC4 n c PC16...

Страница 17: ...2 x 207 x 54 20mm Installation depth 54 20mm The degrees of protection are only guaranteed when the following is observed The material thickness of the installation cut out is 3 12mm The deviation fro...

Страница 18: ...ess level electrically isolated Insulation resistance Insulation voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental condit...

Страница 19: ...50kHz 80MHz 10V 80 AM 1kHz EN 61000 4 4 Burst degree of severity 3 EN 61000 4 5 Surge installation class 3 Due to the high energetic single pulses with Surge an appropriate external protective circuit...

Страница 20: ...0 buffering period Accuracy max deviation per day 10 s Operating controls Touchscreen PCAP Touch function Dual Touch Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUS DP MPI PRO...

Страница 21: ...information alarms diagnostics Supply voltage display none Mechanical data Housing Protection type Material coated aluminium steel plate Mounting via integrated pivoted lever Protect type front side...

Страница 22: ...perties Processor Intel Atom Dualcore 1 86 GHz Operating system Windows embedded Standard 7 User software Work memory 2 GB User memory 16 GB Available memory user data 7 GB SD MMC Slot CF Card Slot Ty...

Страница 23: ...MBit Ethernet connector 2 x RJ45 Integrated ethernet switch Video connectors VGA SubD HD15 Audio connections Line out stereo jack 3 5 mm Technical data power supply Power supply rated value DC 24 V Po...

Страница 24: ...anel 292 mm x 207 mm x 54 2 mm Installation cut out Width 297 mm Height 212 mm Minimum 3 mm Maximum front panel thickness 12 mm Weight 4 kg Environmental conditions Operating temperature 0 C to 50 C S...

Страница 25: ...g tableau and control cabinet fronts the Panel PC requires the following front panel cutting Panel PC W x H in mm 67K PNL0 297 x 212mm The material thickness of the installation cut out is 3 12mm For...

Страница 26: ...ulling the plate 2 With the label facing up insert the CFast card until it is com pletely seated in the slot and reinstall the cover plate After installation the CFast card is automatically recognized...

Страница 27: ...voltage cables 3 3 1 VIPA Startup Manager As soon as the Panel PC is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following st...

Страница 28: ...external keyboard and an USB stick in NTFS format memory size 4GB is necessary The new image file for your Panel PC should be on the USB stick You will find the file under www vipa com in the downloa...

Страница 29: ...imes res projects on the panel and the storage media will be listed n Under Delay Time you can adjust a delay time 0 by using the buttons and 5 seconds are default n Via Rotation the orientation of th...

Страница 30: ...Back you get back to the start screen of the VIPA Startup Man ager 3 4 Connection to a PLC system n For the inclusion into your PLC system several HMI SCADA project engineering platforms are at your d...

Страница 31: ...el n RDP Remote Desktop Protocol n Internet Explorer n WordPad n Mouse pointer n USB keyboard driver Please regard that for the deployment of Windows Embedded Standard 7 a thorough knowledge of operat...

Страница 32: ...en If no object is selected a frame is created by the dragging that selects the touched objects In this version mouse functions are fully supported As soon as the touch screen is touched with the pen...

Страница 33: ...n the task bar The switch between the applications is performed via this but tons 5 Software keyboard This button displays a keyboard at the screen 6 Keyboard layout If you ve connected a keyboard you...

Страница 34: ...nge adapter settings By double click on the network the dialog window for network proper ties opens Here you can enter the Ethernet address via Proper ties after double click on Internet Protocol Vers...

Страница 35: ...ote access choose one of the release options and confirm with OK By default the Panel PC automatically logs in with the user name VIPA and the password vipatp If the user needs to enter name and passw...

Страница 36: ...r a user name and password to use this computer and confirm with Apply 4 A new dialog window opens asking you to enter the log in data Select here your User Name and enter the corresponding password C...

Страница 37: ...window click on Configure 3 In the following window select enable under Pending command to enable the Enhanced Write Filter 4 Confirm with Apply and OK 5 To disable the Enhanced Write Filters select...

Страница 38: ...e changes to the setup program n Resetting the system clock n Redefining the communication ports to prevent any conflicts n Making changes to the power management configuration n Changing the password...

Страница 39: ...lects a field F1 Displays General Help F2 Load previous values F3 Load optimized default values F4 Saves and exits the setup program Enter Enters the highlighted submenu When 4 appears on the left of...

Страница 40: ...plays hours from 00 to 23 n minute displays minutes from 00 to 59 n second displays seconds from 00 to 59 Displays the access level of the current user in the BIOS for example administrator 4 3 Advanc...

Страница 41: ...or disable hyper threading XD can prevent certain classes of malicious buffer overflow attacks Enabled Permit the switching on of the execute disable function by the OS Disabled Prevents the switching...

Страница 42: ...n is used to configure the IDE devices Enables or disables SATA controller Configures the SATA as IDE or AHCI mode IDE This option configures the serial ATA drives as parallel ATA physical storage dev...

Страница 43: ...t support EHCI hand off The EHCI ownership change should be claimed by the EHCI driver Selects the USB mass storage device s start unit command timeout 10 20 30 or 40 seconds This section is used to c...

Страница 44: ...e the mode of serial port 0 as RS232 default RS422 RS485 or RS485 AUTO This section is used to configure serial port 1 Enables or disables the serial port Disabled Serial port is not available Enabled...

Страница 45: ...85 Disabled Terminal resistor not activated Enabled default Terminal resistor activated This section PC Health Status is used to configure the hardware temperature and voltages 4 4 Chipset This sectio...

Страница 46: ...sed to configure which video device will be activated during POST This has no effect if external graphics present The options are CRT LVDS DP LVDS CRT The available options are Pyroelectric sensor and...

Страница 47: ...used to disable or enable SMBus controller This section is used to configure high precision event timer System response when power returns after an AC power failure Last State The system will return...

Страница 48: ...Disabled Displays normal POST messages Upon Request GA20 can be disabled using BIOS services Always Do not allow disabling GA20 this option is useful when any RT code is executed above 1MB This field...

Страница 49: ...inistrator rights Select this to reconfigure the administrator s password Your pass word must contain at least 3 characters and should be maximal 20 characters long Select this to reconfigure the user...

Страница 50: ...lity and reboot the system without saving the changes select this field then press Enter You may be prompted to confirm again before exiting The BIOS setup exits and a restart fol lows To save changes...

Страница 51: ...s Enter A dialog box will appear Confirm by selecting Yes To bypass the boot sequence from the boot option list and boot from a particular device select the desired device and press Enter To launch EF...

Страница 52: ...n EMC planning before installing the compo nents and take conceivable interference causes into account Electromagnetic interferences may interfere your control via different ways n Electromagnetic fie...

Страница 53: ...tive coupling Inductive or magnetic coupling occurs between two current active line loops The magnetic flows associated with the cur rents induct interference vol tages The coupling is propor tional t...

Страница 54: ...tly after the cabinet entry and fix the isolation with cable clamps Make sure that the isolation protected earth conductor rail is connected impedance low with the cabinet Use metallic or metallised p...

Страница 55: ...ted or anodized metal parts in the grounding you have to come through the isolating protection layers For this you may use special contact washers or remove the isolation layer n Protect the connectio...

Страница 56: ...have to be installed in different bundles or cable trusses inside of cubicles and outside of the cubicle but inside the building in separated cable trusses with a min dis tance of 10cm 4 The lines hav...

Страница 57: ...ed by means of equipotential bonding conduc tors to ensure that the electronic equipment employed on the plant operates properly n The lower the impedance of the equipotential bonding conductor the hi...

Страница 58: ...nding conductor n Analogue signals a few mV or mA must be transmitted n Foil type screening static screening is employed You should always use metallic or metallised covers for serial data lines Conne...

Страница 59: ...of DC activated inductors Connections of AC activated inductors using a diode using a Z diode using a varistor using RC net work Every cubicle must be provided with a power outlet for the PU These out...

Страница 60: ...3 Screened cable 4 Switch with metallic cover 5 Line filter or screened power cable Suppression of fluores cent lamps in cubicles VIPA HMI Installation guidelines Special precautions providing high no...

Страница 61: ...been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunch...