8-2
173124-1CD
HW1482991
8 Electrical Equipment Specification
8.2 Internal Connections
MPL300
II
8.2
Internal Connections
Fig. 8-2(a): Internal Connection Diagram
21
-22
-21
-23
22
23
E
-5
-4
-3
-2
-9
-8
-7
-6
-1
-11
-13
-12
-18
-17
-16
-15
-14
-20
-19
-10
1
3
4
5
2
6
9
8
7
10
12
13
15
18
17
16
14
20
19
11
21
-22
-21
-23
22
23
-2
-3
-4
-5
-7
-8
-9
-6
-11
-13
-12
-18
-17
-16
-15
-14
-20
-19
-10
E
1
2
5
6
7
8
4
3
10
9
13
12
16
17
18
15
14
19
20
11
-1
(24-28)
S1
LA1
LB1
S1(24-28)
BC2
BC1
LC2
LD2
DX200
BAT
P
BAT
0BT
P
BAT
P
0BT
0BT
0BT
BAT
P
6
BAT21
0BAT22
BAT22
2
3
4
1
7
8
0BAT11
0BAT21
BAT12
0BAT12
BAT11
4
5
1
3
2
26
32
1
2
31
30
27
29
28
PG0V1
PG5V1
BAT6
0BAT6
20
23
25
24
22
21
17
19
18
BAT2
BAT3
0BAT3
0BAT1
BAT1
0BAT2
8
6
7
5
6
PG5V3
8
7
4
5
3
PG5V2
PG0V3
PG0V2
3
2
4
1
12
13
14
15
16
10
11
9
PG5V6
PG0V6
CN1-5
CN1-4
0V
+24V
+24V
0V
CN1-9
CN1-10
P
P
CN1-10
CN1-4
CN1-5
CN1-9
+24V
+24V
0V
0V
0V
+24V
0V
+24V
-1
-3
-2
-4
1BC(10PX4)
No.20CN
X
No,5CN
-1
-4
-3
-2
BAT1
PG0V1
PG5V1
OBAT1
S
-1
No.1CN
P
P
P
PG
-6
BAT
-10
-9
-5
-4
BAT
OBT
OBT
+5V
0V
FG1
-2
DATA-1
DATA+1
S-AXIS
DATA-2
DATA+2
FG2
-10
BAT
OBT
No,6CN
OBAT2
PG5V2
BAT2
PG0V2
-2
-3
-4
-1
L
No.2CN
-1
-9
-6
-5
-4
-2
0V
BAT
OBT
+5V
L-AXIS
PG
DATA+3
DATA-3
-2
OBAT3
PG0V3
PG5V3
-4
-3
BAT3
No,7CN
-1
U
OBT
-5
-4
-9
-10
BAT
+5V
0V
OBT
FG3
No.3CN
-1
-2
-6
BAT
PG
U-AXIS
DATA-6
DATA+6
OBAT6
PG0V6
PG5V6
BAT6
No,8CN
-2
-3
-4
-1
T
No.4CN
-5
-4
-9
-10
-1
-2
-6
OBT
FG6
+5V
BAT
0V
OBT
BAT
T-AXIS
PG
CN1-1
SPG+1
CN1-2
SPG-1
P
CN1-1
CN1-2
SPG-1
SPG+1
CN1-3
FG1
CN1-3
FG1
CN1-8
FG2
CN1-7
CN1-6
SPG-2
SPG+2
CN1-8
FG2
CN1-7
CN1-6
P
SPG-2
SPG+2
CN2-3
CN2-2
CN2-1
SPG-3
SPG+3
FG3
CN2-3
CN2-2
CN2-1
P
SPG-3
SPG+3
FG3
CN3-8
CN3-7
CN3-6
SPG-6
SPG+6
FG6
CN3-8
CN3-7
CN3-6
P
SPG-6
SPG+6
FG6
LB1
+24V
E
BC2
AL2
CN4-1
CN4-6
CN4-8
CN4-3
LB1
+24V
BC2
AL2
CN4-6
CN4-1
E
CN4-3
CN4-8
AL1
CN4-7
CN4-7
P
P
AL1
CN4-10
0V
CN4-10
LA2
LB2
LC2
LD2
LA2
LB2
LD1
LD2
LB1
LB2
LA3
LB3
LC3
LD3
LB2
LB1
LD2
LD1
CN2-10
CN2-10
+24V
CN2-4
+24V
CN2-4
LD1
CN2-5
P
CN2-5
LD1
LC1
LD1
+24V
+24V
S-AXIS OVERRUN L.S.
L-AXIS OVERRUN L.S.
L AND U-AXIS INTERFERENCE L.S.
LA1
LB1
LB2
LB2
LA2
LB1
A1
A2
A3
Connected to
Connected to
Connected to
S-AXIS OVERRUN L.S.
L-AXIS OVERRUN L.S.
L AND U-AXIS INTERFERENCE L.S.
LC1
LD1
LD2
LD2
LC2
LD1
B1
B2
B3
Connected to
Connected to
Connected to
S-AXIS OVERRUN L.S.
LA1
LB1
LB1
A1
Connected to
S-AXIS OVERRUN L.S.
LC1
LD1
LD1
B1
Connected to
LC1
LD1
LD1
LD2
LD3
LC3
LA1
LB1
LB1
LB2
LB3
LA3
LC1
LA1
P
P
P
P
P
P
P
P
P
A2
B2
A3
B3
A1
B1
AL1
AC1
AL2
AC2
S
FAN
For lamp (option)
For S-axis fan (option)
SLU-axes with Limit Switch Specification
S-axis with Limit Switch Specification
1. For the limit switch specification, the connection of the section
Notes
A
B
and parts are changed as follows:
Internal Wire
62 of 100