9
Battery Pack Replacement
9.1 Battery Pack Replacement
9-2
176183-1CD
HW1483638
MH5S
(II)
/MH5F
Fig. 9-2: Battery Replacement
Fig. 9-3: Battery Connection
1. Turn OFF the DX100/DX200/FS100 main power supply.
2. Unscrew the fixing screws for battery pack and pull out the support
from the connector base.
3. Remove the battery pack from the battery holder.
4. Connect the new battery pack connector to the unoccupied connector
on the board.
5. Remove the old battery pack from the connector on the board.
6. Mount the new battery pack to the holder.
7. Reinstall the support in the connector base with the fixing screws for
the battery pack.
A
View A-A
Battery connector
Connector on the board
Connector on the board
(unoccupied connctor)
A
Fixing screw
for battery pack
Connector
Battery pack
before replacement
New battery pack
Circuit board
(Type: SGDR-EFBA02A)
See step 4 below
See step 5 below
NOTE
Remove the old battery pack after connecting the new one
so that the encoder absolute data does not disappear.
Be careful not to pinch the cables when reinstalling the
battery holder.