3 Setting the Functions
3.2 Setting Method
3-2
156527-1CD
HW1480826
I/O Expansion European
Standard (PNP)
3.2
Setting Method
Switches
Setting Method
S1
Station setting
Sets the stations.
The relation between the switch setting and the station is shown below.
Turn the arrow to the number corresponding to the desired station.
(Use a flat tip screwdriver.)
0: Cannot be set
8: ST#08
1: ST#01
9: ST#09
2: ST#02
A: ST#10
3: ST#03 (Default setting)
B:
ST#11
4: ST#04
C: ST#12
5: ST#05
D: ST#13
6: ST#06
E: Can not be set
7: ST#07
F: Can not be set
The number after ST# is the station number displayed on the programming pendent of
the DX100 when setting I/O modules.
The default setting is ST#03.
JP1
Setting of the
communication speed
Short circuit between 1 and 2: 10 Mbps
*Setting unavailable
Short circuit between 2 and 3: 4 Mbps
(Default setting)
*Setting indispensable
JP2
Setting of the I/O
communication mode
Short circuit between 1 and 2, 5 and 6: 16 byte mode
*Setting unavailable
Short circuit between 3 and 4, 7 and 8: 17 byte mode
(Default setting)
*Setting indispensable
Short circuit between 1 and 2, 3 and 4: 32 byte mode
*Setting unavailable
JP1
10M
4M
3
1
JP1
10M
4M
3
1
32B
17B
16B
JP2
1
2
7
8
32B
17B
16B
JP2
1
2
7
8
32B
17B
16B
JP2
1
2
7
8
NOTE
Do not set S1 to 0, E or F. Do not set more than one board
to one ST#.
Improper settings may prevent the I/O module from being
recognized correctly.
Also, do not set JP1 to 10 Mbps and do not set JP2 to
16 bytes or 32 bytes.
If 10 Mbps, 16 bytes, and 32 bytes are selected, the I/O
module is not recognized.
14/36