4 Option Components
12
YASKAWA ELECTRIC
TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide
◆
Option LED Display
The option has five LEDs.
The operational states of the LEDs are described in
.
Table 3 Option LED States
Note:
The RUN, RX, TX, and ERR LEDs are lit (ON) during initialization of the bind data.
◆
Neuron ID
The neuron ID is written on the side of the service switch. Refer to
details.
The bar code for the neuron ID is included on the device and the packaging.
LED
Name
Display
Operating Status
Explanation (major faults)
Color
Status
RUN
Green
ON
Normal operation
Device is operating normally.
Flashing
Network not configured
LONWORKS network has not been configured.
OFF
Power OFF
No power is being supplied to the drive.
Hardware fault
An unrecoverable fault has occurred.
If the unit does not recover after cycling power, then
the option card may need to be replaced.
RX
Green
ON/
Flashing
Receiving
Receiving node data
OFF
Node data not yet
received
No input signal
TX
Green
ON/
Flashing
Sending Sending
data
OFF
Not sending data
No data is being send
ERR
Red
ON
Hardware fault
An unrecoverable fault has occurred.
If the unit does not recover after cycling power, then
the option card may need to be replaced.
Flashing
Comm error
CALL or BUSS error has occurred
OFF
Normal operation
Device is operating normally.
SERVICE
Green
ON
Service switch active
Service switch is being held down
Hardware fault
An unrecoverable fault has occurred.
If the unit does not recover after cycling power, then
the option card may need to be replaced.
Flashing
Network not configured
LONWORKS network has not been configured
OFF
Normal operation
Device is operating normally.