A.5 Drive Derating Data
A.5
Drive Derating Data
The drive can be operated at above the rated temperature, altitude, and default carrier frequency by derating the drive
capacity.
u
Carrier Frequency Derating
Derate the drive according to
when the carrier frequency is increased above the factory default setting.
Figure A.1
Figure A.1 Carrier Frequency Derating
u
Temperature Derating
To ensure the maximum performance life, the drives output current must be derated when the drive is installed in areas
with high ambient temperature. In order to ensure reliable drive overload protection, the parameters L8-12 and L8-35
must also be set according to the installation conditions.
n
Parameter Settings
According to the settings of parameters L8-12 and L8-35, the drive will be derated as shown in
.
Figure A.2
Figure A.2 Temperature Derating
u
Altitude Derating
The drive standard ratings are valid for an installation altitude up to 1000 m. If the altitude exceeds 1000 m both the drive
input voltage and the rated output current must be derated by 1% per 100 m. The maximum altitude is 3000 m.
No.
Name
Description
Range
Def.
L8-12
Ambient Temperature
Setting
Adjusts the drive overload (oL2) protection level when the drive is installed in an environment
that exceeds its ambient temperature rating.
-10 to 50
40 °C
L8-35
Installation Method
Selection
0: IP20 Enclosure
1: Side-by-Side Mounting
2: NEMA Type 1 Enclosure
3: Finless Drive or External Heatsink Installation
0 to 3
Drive model
(o2-04)
dependent
8
15 kHz
0
2
Drive
Rating
Carrier Frequency (C6-02)
200 V Class:
80% of Output Rating
400 V Class:
60% of Output Rating
100%
40
50
0
30
35
50%
70%
80%
85%
100%
Drive
Rating
Ambient Temp (L8-12)
L8-35 = 0 (IP20/Open-Chassis Drive)
L8-35 = 2
(NEMA Type 1 Drive)
L8-35 = 1
(Side-by-side Mounting)
L8-35 = 3
(Finless Drive or External
Heatsink Installation)
°C
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...