5.11 S: Elevator Parameters
158
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
u
S4: Rescue Operation
Rescue Operation switches to a backup battery or some other UPS during a power outage. Refer to
for details.
n
S4-01: Light Load Direction Search Selection
Enables and disables the Light Load Direction Search.
0: Disabled
1: Enabled
n
S4-02: Light Load Direction Search Method
Determines the method used to perform Light Load Direction Search.
0: Output current
1: Detect direction of regeneration
n
S4-03: Light Load Direction Search Time
Sets the time to perform Light Load Direction Search.
n
S4-04: Light Load Direction Search Speed Reference
Sets the speed reference to use during Light Load Direction Search.
n
S4-05: Rescue Operation Torque Limit
Sets a time limit for Light Load Direction Search.
u
S6: Faults for Elevator Applications
n
S6-01: Motor Contactor Response Error (SE1) Detection/Reset Selection
Determines when the drive should detect a motor contactor response error (SE1). SE1 is triggered if there is no response
from the motor contactor within the time set in S6-10 after the contactor control output has been set.
0: Detect during stop, SE1 must be manually reset
1: Detect during stop, SE1 can be automatically reset
2: No SE1 detection
No.
Parameter Name
Setting Range
Default
S4-01
Light Load Direction Search Selection
0 to 2
0
No.
Parameter Name
Setting Range
Default
S4-02
Light Load Direction Search Method
0 or 1
0
No.
Parameter Name
Setting Range
Default
S4-03
Light Load Direction Search Time
0.0 to 5.0 s
1.0 s
No.
Parameter Name
Setting Range
Default
S4-04
Light Load Direction Search Speed Reference
0.00 to 20.00%
Determined by A-02
No.
Parameter Name
Setting Range
Default
S4-05
Rescue Operation Torque Limit
0 to 300%
100%
No.
Parameter Name
Setting Range
Default
S6-01
Motor Contactor Response Error (SE1) Detection/Reset Selection
0 to 2
0
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...