5.11 S: Elevator Parameters
YASKAWA EUROPE
SIEP
YASKAWA AC Drive L1000V Technical Manual
156
5
5.11 S: Elevator Parameters
This section describes various functions and faults needed to operate an elevator application: braking sequence, slip
compensation, optimal adjustments at start and stop, Rescue Operation, and elevator-related faults.
u
S1: Brake Sequence
The drive supports braking sequences using an analog input terminal to control torque compensation at start (H3-
=
14), and braking sequences that do not require an analog input to set the torque compensation level. Refer to
for details.
n
S1-01: Zero Speed Level at Stop
Determines the speed to begin applying DC Injection when the drive is ramping to stop (b1-03 = 0). Set as a percentage
of the maximum output frequency (E1-04).
Parameter S1-01 sets the starting speed for DC Injection Braking at stop. Once the output speed falls below the setting of
S1-01, the amount of DC Injection Braking current set in S1-03 is injected into the motor for the time set in parameter
S1-05.
n
S1-02: DC Injection Current at Start
Determines the amount of current to use for DC Injection at start. Set as a percentage of the drive rated current.
n
S1-03: DC Injection Current at Stop
Determines the amount of current to use for DC Injection at stop. Set as a percentage of the drive rated current. When
using OLV Control, the DC injection current is determined by multiplying S1-03 by S3-25 or S3-26.
n
S1-04: DC Injection Time at Start
Determines how long the drive should perform DC Injection at start. During this time, the drive allows motor flux to
develop, which is essential for applying torque quickly once the brake is released. A setting of 0.00 disables S1-04.
n
S1-05: DC Injection Time at Stop
Determines how long the drive should perform DC Injection at stop. A setting of 0.00 disables S1-05.
n
S1-06: Brake Release Delay Time
Determines the time that must pass after an Up/Down command is entered before the output terminal set for "Brake
control" (H2-
= 50) is triggered.
Adjusting this delay time can help when there is not enough time to develop the appropriate amount of motor flux. Be
sure to also increase the time S1-04 when setting S1-06 to relatively long delay time.
No.
Parameter Name
Setting Range
Default
S1-01
Zero Speed Level at Stop
0.000 to 9.999%
Determined by A1-02
No.
Parameter Name
Setting Range
Default
S1-02
DC Injection Current at Start
0 to 75%
50%
No.
Parameter Name
Setting Range
Default
S1-03
DC Injection Current at Stop
0 to 100%
50%
No.
Parameter Name
Setting Range
Default
S1-04
DC Injection / Position Lock Time at Start
0.00 to 10.00 s
0.40 s
No.
Parameter Name
Setting Range
Default
S1-05
DC Injection / Position Lock Time at Stop
0.00 to 10.00 s
0.60 s
No.
Parameter Name
Setting Range
Default
S1-06
Brake Release Delay Time
0.00 to 10.00 s
0.20 s
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...