5.3 C: Tuning
■ C6-21: Inspection Operation Carrier Frequency
Sets the carrier frequency during Inspection Run.
No.
Parameter Name
Setting Range
Default
C6-21
Inspection Operation Carrier Frequency
0 or 1
1
Setting 0: Use the value set to C6-03
Setting 1: 2 kHz
■ C6-23: Carrier Frequency during Initial Motor Pole Search
Sets the carrier frequency when estimating the initial polarity.
No.
Parameter Name
Setting Range
Default
C6-23
Carrier Frequency during Initial Motor Pole Search
0 or 1
0
Setting 0: 2 kHz
Setting 1: Use the value set to C6-03
■ C6-31: Carrier Frequency during Rescue Operation
Note: Available in drive software PRG: 7016 and later.
Sets the carrier frequency during Rescue Operation.
No.
Parameter Name
Setting Range
Default
C6-31
Carrier Frequency during R escue Operation
0, 1
0
0: Use the value set to C6-03
1: 2 kHz
Ч _
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual
153
P
a
ra
m
e
te
r
D
e
ta
il
s
Содержание L1000A Series
Страница 68: ...3 11 Wiring Checklist 72 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 264: ...6 8 Diagnosing and Resetting Faults 268 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 308: ...8 5 Installing Peripheral Devices 312 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 316: ...A 5 Drive Derating Data 320 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...
Страница 390: ...C 12 Self Diagnostics 394 YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual...