![YASKAWA JEPMC-MP2300 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/yaskawa/jepmc-mp2300/jepmc-mp2300_user-manual_907070050.webp)
2 Module Specifications
2.2.5 Setting SVB Module
2-22
( 2 ) SVB Definition
The SVB Definition file defines the motion parameters (motion fixed parameters, motion setting parameters, and
motion monitoring parameters) to control motion axes such as the SERVOPACK, inverter, and stepper.
Refer to
D Motion Parameter Lists
on page A-19 for details on motion parameters.
[ a ] Opening the
SVB Definition
Window
Open the
SVB Definition
Window by the following procedure.
1.
Double-click the slot number cell of the SVB Module in the
Module Details
field in the Module
Configuration
Window (refer to
2.2.2 ( 1 ) Module Configuration Window Components
on page 2-8).
The
Create New Confirmation
Dialog Box will open. Click
OK
to display the
Fixed Parameters
Tab of the
SVB Definition
Window.
2.
Select the axis to be set or monitored from the
Axis
pull-down list.
Axis
corresponds to
ST#
(station number) in the
Link Assignment
Tab of the
MECHATROLINK
Transmission Definition
Window.