![background image](http://html.mh-extra.com/html/yaskawa/jepmc-mp2300/jepmc-mp2300_user-manual_907070160.webp)
5 Outline of Motion Control Systems
5.2.4 Motion Programs and MSEE and S Registers
5-12
5.2.4 Motion Programs and MSEE and S Registers
Motion program status, control signal, interpolation override, and system work number data is saved in four MSEE
registers (4 words) with a DA
(
: hexadecimal number) leading address. This data is called every time the
MSEE command is executed in an H drawing. Motion program execution information can be monitored in the S regis-
ters.
The following figure shows the method for executing motion programs. MSEE register details and S register descrip-
tions are also provided below from (1) onwards.
For the meaning of register numbers and how to interpret them, refer to
5.3 Registers
on page 5-21.
( 1 ) Motion Program Status Bits (DA
+0)
The leading word (DA
+0) in the MSEE work registers contains the motion program status bits for monitor-
ing execution status of the motion program.
The following table shows details of status bit.
Alarm details are saved in the S registers.
VEL [a1] 5000 [b1]..
FMX T10000000;
IAC T25;
IDC T30;
MOV [a1] 300. [b1]..
MVS [a1] 200. [b1]..
.
.
.
.
DA
DA
+1
DA
+2
DA
+3
(
: hexadecimal number)
END
DWG.H
DEND
.
.
.
.
.
.
.
.
Status
Control signal
Interpolation override
System work number
MSEE
work registers
address
External ladder control
signal
•
Operation start
•
Pause
•
Stop, etc.
Ladder program for
motion program control
Motion
program No.
MPM001
Execution control using
motion management function
Motion program
MSEE work registers
leading address
Calling MSEE work
registers
Bit No.
Status
0
Program running
1
Program paused
2
Program stopped by stop request (used by system)
3
(Used by system)
4
Single program block operation stopped
8
Program alarm
9
Stopped by brake point
B
In debug mode (EWS debugging operation)
D
Start request signal history
E
No system work error
F
Main program number exceeded error