6.4 Operating the Gateway Unit
6.4.2 Setting the Gateway Parameters
6-12
M-II Port Communications Settings
Link Assignments
No.
(hex)
Data Size
[Bytes]
Name
Description
Default
0201
2
Number of M-II Transmission Bytes
0: 17 bytes
1: 32 bytes
1
0202
2
M-II Transmission Cycle
0: 0.5 ms
1: 1 ms
2: 1.5 ms
3: 2 ms
4: 3 ms
5: 4 ms
1
0204
2
Number of Slave Station Retries
0 to 7
0
0205
2
Number of Connected Nodes
0 to 8
0
No.
(hex)
Data Size
[Bytes]
Name
Description
Default
0300
2
#1 Station Address
0 or 20 hex or higher
0
0301
2
#1 Type
0: No data assigned.
1: Intelligent I/O
2: Simple I/O
3: Servo Drive
4: Stepping Motor Drive
5: Inverter
0
0302
2
#1 Assigned Station
0 to 4
0
0303
2
#1 Input Offset
0 to 63
0
0304
2
#1 Input Data Size
0 to 31
0
0305
2
#1 Output Offset
0 to 63
0
0306
2
#1 Output Data Size
0 to 31
0
0400
2
#2 Station Address
0 or 20 hex or higher
0
0401
2
#2 Type
0: No data assigned.
1: Intelligent I/O
2: Simple I/O
3: Servo Drive
4: Stepping Motor Drive
5: Inverter
0
0402
2
#2 Assigned Station
0 to 4
0
0403
2
#2 Input Offset
0 to 63
0
0404
2
#2 Input Data Size
0 to 31
0
0405
2
#2 Output Offset
0 to 63
0
0406
2
#2 Output Data Size
0 to 31
0
0500
2
#3 Station Address
0 or 20 hex or higher
0
0501
2
#3 Type
0: No data assigned.
1: Intelligent I/O
2: Simple I/O
3: Servo Drive
4: Stepping Motor Drive
5: Inverter
0
0502
2
#3 Assigned Station
0 to 4
0
0503
2
#3 Input Offset
0 to 63
0
0504
2
#3 Input Data Size
0 to 31
0
0505
2
#3 Output Offset
0 to 63
0
Continued on next page.