background image

3 Receiving and System Components

YASKAWA

TOEPYAIH6R01B HV600 REDUNDANT DRIVE OPERATIONAL TEST MANUAL

7

Models (H6RxBxxx)

Rated Input

Voltage

Rated Output

Current (Amps)

Redundant Drive Package

Model No. H6RxBxxx

Nominal HP

*1

Dimensions (in)

H

W

D

480 V Three-

Phase

4.8

005

3

43.5

26.6

21.4

7.6

008

5

11

011

7.5

14

014

10

21

021

15

27

027

20

34

034

25

40

040

30

55.0

33.2

26.2

52

052

40

65

065

50

77

077

60

96

096

75

124

124

100

156

156

125

85.4

41.3

34.4

180

180

150

240

240

200

Contact Yaskawa

302

302

250

*1

Horsepower rating is based on standard NEMA B, 4-pole motor design as represented in NEC table 430.150 Full Load Current, Three-
Phase Alternating Current Motors at 480 volts.

3

Receiving and System Components

Do these tasks after you receive the Redundant Drive Package:

Inspect the package for damage. Contact the shipper immediately if the package appears damaged upon receipt.

Verify receipt of the correct model by checking the catalog code printed on the nameplate of the package.

Contact your supplier if you have received the wrong model or the package does not function properly.

Содержание H6R B Series

Страница 1: ...YA I H 6 R 0 1 M O D E L S H6RxBxxx Three Phase 480 V 3 to 250 HP A C D R I V E F O R H VA C F A N P U M P A P P L I C AT I O N S R E D U N D A N T D R I V E O P E R AT I O N A L T E S T M A N U A L...

Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIH6R01B HV600 REDUNDANT DRIVE OPERATIONAL TEST MANUAL...

Страница 3: ...mental Safety Information 4 General Safety 4 2 Product Overview 5 How to Read Redundant Drive Catalog Codes 6 Models H6RxBxxx 7 3 Receiving and System Components 7 4 Primary Operation Tests 10 Primary...

Страница 4: ...manual and the standard drive manuals General Safety General Precautions Some figures in the instructions include options and drives without covers or safety shields to more clearly show the inside o...

Страница 5: ...dant Drive Package is engineered for use in critical HVAC building automation applications that require continuous reliable motor control This document provides a procedure to test the operation of th...

Страница 6: ...Drive Catalog Codes Use the information in Figure 2 1 and Table 2 2 to read the catalog codes Figure 2 1 Catalog Code Table 2 2 Catalog Code Details No Description 1 HV600 Redundant Drive 2 Enclosure...

Страница 7: ...3 34 4 180 180 150 240 240 200 Contact Yaskawa 302 302 250 1 Horsepower rating is based on standard NEMA B 4 pole motor design as represented in NEC table 430 150 Full Load Current Three Phase Altern...

Страница 8: ...PLY 24VDC 150 mA MAX P OPTION CARD SHIELD GND FE COMMUNICATIONS INPUT R COMMUNICATIONS INPUT R COMMUNICATIONS OUTPUT S COMMUNICATIONS OUTPUT S JUMPER SH1 to 122 SH1 from 124 RUNNING DRIVE ON POWER FAU...

Страница 9: ...d Current FLA Must be set by user H1 05 6E Terminal Sx Function Selection HAND Command ON HAND Mode OFF OFF Mode or AUTO Mode H1 06 18 Terminal Sx Function Selection Timer Function H1 07 6D Terminal S...

Страница 10: ...10 22 TB1 1SN 138 127 127 to 125 127 from 129 127 128 128 to 125 128 from 129 128 RUNNING DRIVE ON POWER FAULT DRIVE AGREE 1 SPEED RUN FWD S1 RUN REV S2 EXTERNAL FAULT N O S3 FAULT RESET S4 HAND MODE...

Страница 11: ...if necessary set min max speeds and accel decel times etc 11 When commissioning is complete set the HAND OFF AUTO switch to OFF to stop the drive Expanded Function Test Table 4 3 Expanded Function Te...

Страница 12: ...rt Drive A 19 Confirm that you can use the BAS to change the speed reference for Drive A and Drive B 20 If necessary remove the front cover from Drive A to access the TB3 and TB4 terminal blocks below...

Страница 13: ...TIONAL TEST MANUAL 13 Revision History Date of Publication Revision Number Revised Content April 2023 2 Revision Applicable Documents and Catalog Code February 2023 1 Revision Document title Addition...

Страница 14: ...yaskawa eu com www yaskawa eu com YASKAWA EL TRICO DO BRASIL LTDA 777 Avenida Piraporinha Diadema S o Paulo 09950 000 Brasil Phone 55 11 3585 1100 Fax 55 11 3585 1187 www yaskawa com br In the event t...

Отзывы: