7-8
Registers
Drive Parameter Registers (U1-XX / Monitor Only) (continued)
REGISTER
PARAMETER
PARAMETER
PARAMETER
BIT
LIMITS / DESCRIPTION
(in hex)
FUNCTION
SETTING
NO.
02Bh
U1-12
Operation Status
0
Run
1
Zero-Speed
2
Reverse Run
3
Reset Signal Input
4
Speed Agree
5
Drive Operation Ready
6
Minor Fault
7
Major Fault
02Ch
U1-13
Elapsed Time
hours
02Dh
U1-14
Software No. (CPU ID No.)
software version number
02Eh
U1-15
Control Circuit Term 13 Input Voltage
Input voltage signal at terminal 13 (+10V / +100.0%
∼
-10V / -100.0%)
02Fh
U1-16
Control Circuit Term 14 Input Voltage Input voltage or mAmp signal at terminal 14 (+10V / +100.0%
∼
-10V / -
100.0%) or (4mA / 0.0%
∼
20mA / 100.0%)
030h
U1-17
Control Circuit Term 16 Input Voltage
Input voltage signal at terminal 16 (+10V / +100.0%
∼
-10V / -100.0%)
031h
U1-18
Motor Secondary Current (Iq)
Motor Secondary Current-Iq (0.1%)
032h
U1-19
Motor Exciting Current (Id)
Motor Rated Primary Current-Id (0.1%)
033h
U1-20
Output Frequency after Soft-start
Max. Output Frequency (0.01 Hz)
034h
U1-21
Automatic Speed Regulator (ASR)
Input
ASR Input (0.01%)
035h
U1-22
Automatic Speed Regulator (ASR)
Output
ASR Output (0.01%)
036h
U1-23
Speed Deviation Regulator Input
Speed Deviation Regulator Input (0.01%)
037h
U1-24
PID Feedback Amount
PID Feedback Amount (0.01%)
038h
U1-25
DI - 16 H Input Status
displays an input value according to the setting of F3-01
039h
U1-26
Output Voltage Reference Vq
Output Voltage-Vq (0.1V)
03Ah
U1-27
Output Voltage Reference Vd
Output Voltage-Vd (0.1V)
03Bh
U1-28
Software No. CPU
processor version number
03Dh
U1-32
ACR Output q Axis
ASR Output q Axis (0.1%)
03Eh
U1-33
ACR Output d Axis
ASR Output d Axis (0.1%)
03Fh
U1-34
OPE Detected
parameter setting error