11.22 Parameters Changed by PM Motor Code Selection
630
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
No.
Name
Unit
Motor Code (setting value of E5-01)
E1-04
Maximum Output
Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-05
Maximum Output Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
87.5
87.5
87.5
E1-09
Minimum Output
Frequency
Hz
4.4
4.4
4.4
4.4
4.4
4.4
4.4
C5-17
Motor Inertia
kgm
2
0.55
0.82
0.96
1.60
1.95
2.82
3.70
L3-24
Motor Accel Time @ Rated
Torque
s
0.205
0.250
0.244
0.336
0.327
0.379
0.414
n5-02
Motor Inertia Acceleration
Time
s
0.205
0.250
0.244
0.336
0.327
0.379
0.414
n8-49
Heavy Load Id Current
%
-8.6
-14.8
-17.5
-12.5
-14.7
-5.1
-16.3
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 11.26 SST4 Series Motor Code Setting for Specification of 200 V at 1450 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
-
2302
2303
2305
2306
2308
230A
230B
230D
Voltage Class
V
200
200
200
200
200
200
200
200
Capacity
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
Motor Rotation Speed
min
-1
1450
1450
1450
1450
1450
1450
1450
1450
E5-02
PM Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
E5-03
PM Motor Rated Current
(FLA)
A
1.77
3.33
5.94
9.48
14.17
20.42
27.92
39.6
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
6
6
E5-05
PM Motor Resistance
(ohms/phase)
Ω
3.154
1.835
0.681
0.308
0.405
0.278
0.180
0.098
E5-06
PM d-axis Inductance
(mH/phase)
mH
28.46
19.46
10.00
6.88
8.15
5.77
6.32
3.34
E5-07
PM q-axis Inductance
(mH/phase)
mH
39.29
25.89
15.20
9.25
10.76
8.60
8.80
4.61
E5-09
PM Back-EMF Vpeak
(mV/(rad/s))
mVs/rad
268.8
256.9
271.9
260.2
286.8
314.9
300.8
292.3
E5-24
PM Back-EMF L-L
Vrms (mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output
Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output
Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output
Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
C5-17
Motor Inertia
kgm
2
0.0016
0.0022
0.0081
0.0133
0.0133
0.017
0.027
0.044
L3-24
Motor Accel Time @
Rated Torque
s
0.092
0.068
0.125
0.139
0.083
0.070
0.082
0.092
n5-02
Motor Inertia
Acceleration Time
s
0.092
0.068
0.125
0.139
0.083
0.070
0.082
0.092
n8-49
Heavy Load Id Current
%
-7.5
-9.4
-13.9
-10.0
-15.0
-17.9
-22.7
-20.5
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...