1.22 Parameters Changed by PM Motor Code Selection
YASKAWA
TOEPYAIGA8002B GA800 Drive Programming
155
Table 1.10 SSR1 Series Motor Code Setting for Specification of 400 V at 1750 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection
-
1247
1248
1249
124A
Voltage Class
V
400
400
400
400
Capacity
kW
90
110
132
160
Motor Rotation Speed
min
-1
1750
1750
1750
1750
E5-02
PM Motor Rated Power
kW
90.00
110.00
132.00
160.00
E5-03
PM Motor Rated Current (FLA)
A
160.4
183.3
222.9
267.7
E5-04
PM Motor Pole Count
-
6
6
6
6
E5-05
PM Motor Resistance (ohms/phase)
Ω
0.019
0.017
0.012
0.008
E5-06
PM d-axis Inductance (mH/phase)
mH
1.54
1.44
1.21
0.97
E5-07
PM q-axis Inductance (mH/phase)
mH
2.06
2.21
1.46
1.28
E5-09
PM Back-EMF Vpeak (mV/(rad/s))
mVs/rad
524.1
583.7
563.6
601.2
E5-24
PM Back-EMF L-L Vrms (mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
87.5
87.5
87.5
87.5
E1-05
Maximum Output Voltage
V
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
87.5
87.5
87.5
87.5
E1-09
Minimum Output Frequency
Hz
4.4
4.4
4.4
4.4
C5-17
Motor Inertia
kgm
2
0.56
0.83
0.96
1.61
L3-24
Motor Accel Time @ Rated Torque
s
0.208
0.254
0.243
0.338
n5-02
Motor Inertia Acceleration Time
s
0.208
0.254
0.243
0.338
n8-49
Heavy Load Id Current
%
-17.0
-21.7
-10.9
-13.2
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 1.11 SSR1 Series Motor Code Setting for Specification of 200 V at 1450 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
-
1302
1303
1305
1306
1308
130A
130B
130D
Voltage Class
V
200
200
200
200
200
200
200
200
Capacity
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
Motor Rotation Speed
min
-1
1450
1450
1450
1450
1450
1450
1450
1450
E5-02
PM Motor Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
E5-03
PM Motor Rated Current
(FLA)
A
1.88
3.13
5.63
8.33
14.17
20.63
27.71
39.6
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
6
6
E5-05
PM Motor Resistance
(ohms/phase)
Ω
3.190
1.940
1.206
0.665
0.341
0.252
0.184
0.099
E5-06
PM d-axis Inductance
(mH/phase)
mH
32.15
26.12
14.72
12.27
8.27
6.49
6.91
4.07
E5-07
PM q-axis Inductance
(mH/phase)
mH
41.74
34.30
20.15
14.77
9.81
7.74
7.66
4.65
E5-09
PM Back-EMF Vpeak
(mV/(rad/s))
mVs/rad
264.3
269.6
284.3
287.1
284.5
298.0
335.0
303.9
E5-24
PM Back-EMF L-L
Vrms (mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output
Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum Output
Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5