3.2 Overview of Keypad Components and Functions
464
YASKAWA
TOEPYAIGA5002A GA500 Programming
Figure 3.7 Key Operation Examples for Parameter Settings
◆
Verify and Set the Changed Parameters (Verify Menu)
Show the frequency reference screen.
Note:
Push and hold
to return to frequency reference screen from any screen.
Use Verify mode to view all parameters that are not at default settings. This is very useful when you replace a drive.
When there are no changes to parameter settings, the display shows
. This lets you quickly access and re-edit
changed parameters.
shows the procedure.
Note:
The drive will only display
A1-02 [Control Method Selection]
,
A1-xx
,
A2-01 to A2-32 [User Parameter 1 to User Parameter 32]
, and
E5-01
[PM Motor Code Selection]
.
Figure 3.8 Verify and Set the Changed Parameters
◆
How to Switch between LOCAL and REMOTE
LOCAL mode lets you use the keypad to input Run commands. REMOTE mode lets you use other sources than the
keypad to input Run commands.
WARNING!
Sudden Movement Hazard. If you change the control source when b1-07 = 1 [LOCAL/REMOTE Run Selection = Accept
Existing RUN Command], the drive can start suddenly. Before you change the control source, remove all personnel from the area
around the drive, motor, and load. Sudden starts can cause serious injury or death.
You can use
or MFDI functions (LOCAL/REMOTE Selection) to switch between LOCAL and REMOTE.
Note:
1.
illuminates while the drive is in LOCAL Mode.
2. While you are entering a Run command, you cannot switch between LOCAL and REMOTE.
Содержание GA500 series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...