1.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
YASKAWA
TOEPYAIGA5002A GA500 Programming
109
No.
Name
Range
Unit
Control Method (A1-02 Setting)
V/f
(0)
OLV
(2)
E1-04
Maximum Output
Frequency
40.0 - 400.0
0.1 Hz
60.0
60.0
E1-05
Maximum Output Voltage
0.0 - 255.0
0.1 V
200.0
E1-06
Base Frequency
0.0 - 400.0
0.1 Hz
60.0
60.0
E1-07
Mid Point A Frequency
0.0 - 400.0
0.1 Hz
3.0
E1-08
Mid Point A Voltage
0.0 - 255.0
0.1 V
15.0
11.0
E1-09
Minimum Output
Frequency
0.0 - 400.0
0.1 Hz
0.5
E1-10
Minimum Output Voltage
0.0 - 255.0
0.1 V
2.0
F1-09
Overspeed Detection Delay
Time
0.0 - 2.0
0.1 s
-
-
L1-01
Motor Overload (oL1)
Protection
0 - 4
1
2
2
L2-31
KEB Start Voltage Offset
Level
0 - 100
1 V
0
0
L3-05
Stall Prevention during
RUN
0 - 3
1
1
1
L3-20
DC Bus Voltage Adjustment
Gain
0.00 - 5.00
0.01
1.00
0.30
L3-21
OVSuppression Accel/
Decel P Gain
0.10 - 10.00
0.01
1.00
1.00
L3-36
Current Suppression
Gain@Accel
0.0 - 100.0
0.1
10.0
20.0
L4-01
Speed Agree Detection
Level
0.0 - 400.0
0.1
0.0 Hz
0.0 Hz
L4-02
Speed Agree Detection
Width
0.0 - 20.0
0.1
2.0 Hz
2.0 Hz
L4-03
Speed Agree Detection
Level(+/-)
-400.0 - +400.0
0.1
0.0 Hz
0.0 Hz
L4-04
Speed Agree Detection
Width(+/-)
0.0 - 20.0
0.1
2.0 Hz
2.0 Hz
L8-40
Carrier Freq Reduction Off-
Delay
0.00 - 2.00
0.01 s
0.50
0.50
L8-90
STPo Detection Level (Low
Speed)
0 - 5000
1
-
-
n5-04
Speed Response Frequency
0.00 - 500.00
0.00 Hz
-
-
n8-35
Initial Pole Detection
Method
0 - 2
1
-
-
n8-51
Pull-in Current @
Acceleration
0 - 200%
1
0
0
o1-03
Frequency Display Unit
Selection
0 - 3
1
0
0
o1-04
V/f Pattern Display Unit
0 - 1
1
-
-
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
*2
The default setting changes when the setting of
C6-01 [Normal / Heavy Duty Selection]
changes.
*3
The setting range changes when the setting of
E5-01 [PM Motor Code Selection]
changes when
A1-02 = 5 [OLV/PM]
.
*4
The default setting changes when the drive model and
E1-03 [V/f Pattern Selection]
change.
*5
This is the value for 200 V class drives. Double the value for 400 V class drives.
*6
When
A1-02 = 5 [OLV/PM]
, the maximum value of the setting range is 100.0.
*7
When
A1-02 = 5 [OLV/PM]
, the setting range is -100.0 to +100.0.
Содержание GA500 series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Страница 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...