84
YASKAWA ELECTRIC
TOEP C710687 03B FSDrive-MV1000 Parameter Guide
1.4 Control Mode Dependent Parameter Default Values
1.4 Control Mode Dependent Parameter Default Values
The tables below list the parameters that depend on the control mode selection (A1-02 for motor 1, E3-01 for motor 2).
Changing the control mode initializes these parameters to the values shown here.
u
A1-02 (Motor 1 Control Mode) Dependent Parameters
Table 1.2 A1-02 (Motor 1 Control Mode) Dependent Parameters and Default Values
No.
Name
Setting Range
Resolution
Control Modes (A1-02)
V/f (0)
OLV (2)
CLV (3)
A3-01
Trace Data 01
0 to 899
–
101
101
101
A3-02
Trace Data 02
0 to 899
–
102
102
102
A3-03
Trace Data 03
0 to 899
–
103
103
103
A3-04
Trace Data 04
0 to 899
–
106
105
105
A3-05
Trace Data 05
0 to 899
–
107
106
106
A3-06
Trace Data 06
0 to 899
–
110
107
107
A3-07
Trace Data 07
0 to 899
–
111
109
109
A3-08
Trace Data 08
0 to 899
–
112
110
110
A3-09
Trace Data 09
0 to 899
–
113
111
111
A3-10
Trace Data 10
0 to 899
–
116
112
112
A3-11
Trace Data 11
0 to 899
–
149
113
113
A3-12
Trace Data 12
0 to 899
–
152
116
116
A3-13
Trace Data 13
0 to 899
–
154
149
149
A3-14
Trace Data 14
0 to 899
–
408
152
152
A3-15
Trace Data 15
0 to 899
–
416
154
154
A3-16
Trace Data 16
0 to 899
–
418
408
408
A3-17
Trace Data 17
0 to 899
–
419
416
416
A3-18
Trace Data 18
0 to 899
–
421
418
418
A3-19
Trace Data 19
0 to 899
–
601
419
419
A3-20
Trace Data 20
0 to 899
–
618
421
421
A3-21
Trace Data 21
0 to 899
–
000
601
601
A3-22
Trace Data 22
0 to 899
–
000
602
602
A3-23
Trace Data 23
0 to 899
–
000
605
603
A3-24
Trace Data 24
0 to 899
–
000
606
604
A3-25
Trace Data 25
0 to 899
–
000
607
605
A3-26
Trace Data 26
0 to 899
–
000
608
606
A3-27
Trace Data 27
0 to 899
–
000
618
607
A3-28
Trace Data 28
0 to 899
–
000
000
608
A3-29
Trace Data 29
0 to 899
–
000
000
618
A3-30
Trace Data 30
0 to 899
–
000
000
000
A3-31
Trace Data 31
0 to 899
–
000
000
000
A3-32
Trace Data 32
0 to 899
–
000
000
000
b2-01
Zero Speed Level (DC Injection Braking
Start Frequency)
0.0 to 10.0
0.1
0.5 Hz
0.5 Hz
0.5 Hz
b2-04
DC Injection Braking Time at Stop
0.00 to 10.00
0.01 s
0.50
0.50
0.50
b3-01
Speed Search Selection at Start
0 to 1
–
0
0
–
b3-02
Speed Search Deactivation Current
0 to 200
1%
70
30
–
b5-15
PID Sleep Function Start Level
0.0 to 120.0
0.1
0.0 Hz
0.0 Hz
0.0 Hz
b6-01
Dwell Reference at Start
0.0 to 120.0
0.1
0.0 Hz
0.0 Hz
0.0 Hz
b6-03
Dwell Reference at Stop
0.0 to 120.0
0.1
0.0 Hz
0.0 Hz
0.0 Hz
C1-11
Accel/Decel Time Switching Frequency
0.0 to 120.0
0.1
0.0 Hz
0.0 Hz
0.0 Hz
C2-01
S-Curve Characteristic at Accel Start
0.00 to 10.00
0.01 s
0.20
0.20
0.20
C3-01
Slip Compensation Gain
0.0 to 2.5
0.1
0.0
1.0
1.0
C3-02
Slip Compensation Primary Delay Time
0 to 10000
1 ms
3000
3000
–
C3-05
Output Voltage Limit Operation Selection
0 to 1
–
–
0
1
C4-01
Torque Compensation Gain
0.00 to 2.50
0.01
1.00
1.00
–
C4-02
Torque Compensation Primary Delay Time 1
0 to 10000
1 ms
200
50
–
MV1000ParameterGuide_E_conditional.book 84 ページ 2013年10月11日 金曜日 午後8時18分