3.2 Operating Procedures for Utility Functions
3.2.9 Manually Adjust Speed Reference Offset (Fn00A)
3-25
3
Utility Function
s
3.2.9
Manually Adjust Speed Reference Off-
set (Fn00A)
You can use this utility function to directly input an offset to adjust the
speed reference. The offset is adjusted manually in the following cases.
•
When a position loop is created with the host computer and the posi-
tion deviation when the Servomotor is stopped by a servo lock is to be
set to 0
•
To intentionally set the offset to a desired value
•
To check an offset that was set automatically
Preparations
Always check the following before you manually adjust the speed refer-
ence offset.
•
The parameters must not be write-prohibited (Fn010 must be set to
0000).
The offset does not use a parameter, so it will not change even
if the parameter settings are initialized.
Example