11 Appendix
11.3.2 List of Parameters
11-16
Pn001
Function Selection Application Switches 1
−
−
0000
After restart
Pn002
Function Selection Application Switches 2
−
−
0000
After restart
Parameter
No.
Name
Setting Range
Units
Factory
Setting
Setting
Validation
0
1
2
0
1
2
Stops the motor by applying dynamic brake (DB).
Stops the motor by applying dynamic brake (DB) and then releases DB.
Makes the motor coast to a stop state without using the dynamic brake (DB).
Same setting as Pn001.0 (Stops the motor
by applying DB
or
by coasting
).
Sets the torque of Pn406 to the maximum value,
decelerate the motor to a stop
, and then sets it
to
servolock state
.
Sets the torque of Pn406 to the maximum value,
decelerates the motor to a stop
, and then sets it
to
coasting state
.
Servo OFF or Alarm Stop Mode
Overtravel (OT) Stop Mode
0
1
Not applicable to main circuit DC power input: Input AC power supply through L1, L2, and L3
terminals.
AC/DC Power Input Selection
0
1
ALO1, ALO2, and ALO3 output only
alarm codes.
Warning Code Output Selection
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Applicable to main circuit DC power input: Input DC power supply between + 1 and
㧙
ALO1, ALO2, and ALO3 output both
alarm codes
and
warning codes
. While warning
codes are output, ALM signal output remains ON (normal state).
0
0
1
N/A
Uses V-REF as an
external speed limit input.
Speed Control Option (T-REF Terminal Allocation)
Torque Control Option (V-REF Terminal Allocation)
0
1
Uses absolute encoder as an
absolute encoder
.
Uses absolute encoder as an
incremental encoder.
Absolute Encoder Usage
Reserved (Do not change)
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
N/A
Uses T-REF as an
external torque limit input
.
(Refer to "8.9.3 Torque Limiting Using an Analog Voltage Reference.")
Uses T-REF as a
torque feed forward input
.
(Refer to "9.4.2 Torque Feed-forward.")
Uses T-REF as an
external torque limit input when P-CL and N-CL are ON.
(Refer to "8.9.4 Torque Limiting Using an External Torque Limit and Analog Voltage Reference.")
1
2
3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com