![YASKAWA E-II Series Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/yaskawa/e-ii-series/e-ii-series_user-manual_3758633126.webp)
5 Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.5.18 Fully-closed Application Module
5-44
5.5.18 Fully-closed Application Module
(1) Model: JUSP-FC100
(2) Specifications
(3) Dimensional Drawings
Item
Details
Applicable SERVOPACK
All SGDH-
EB models
Installation Method
Mounted on the SGDH SERVOPACK side: CN10.
Basic
Specifications
Power Supply Method
Supplied from the SERVOPACK control power supply.
Power Consumption
0.5 W or less
Fully Closed
System
Specifications
Fully-closed Encoder Pulse
Output Form
5 V differential line-driver output (complies with EIA Standard
RS-422A)
Fully-closed Encoder Pulse
Signal Form
90
°
Phase difference 2-phase differential pulse (phase A, phase B)
Maximum Receivable Fre-
quency for SERVOPACK
1 Mbps
Power Supply for Fully-
closed Encoder
To be prepared by customer.
Internal Functions
Protection
Detecting fully-closed encoder disconnection
LED Indicators
Setting with the parameters
128
(24)
CN4
142
(100)
20
FC100
Nameplate
M4
Units: mm
Approx. mass: 0.2 kg
FG terminal
Connector
To SERVOPACK
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com