6.12 Absolute Encoders
6.12.9 Multiturn Limit Disagreement Alarm (A.CC0)
6-80
•
If the motor operates in the reverse direction when the multiturn data is 0, the multiturn data
will change to the value set in Pn205.
•
If the motor operates in the forward direction when the multiturn data is at the value set in
Pn205, the multiturn data will change to 0.
Set Pn205 to one less than the desired multiturn data.
6.12.9
Multiturn Limit Disagreement Alarm (A.CC0)
If you change the multiturn limit in Pn205 (Multiturn Limit), an A.CC0 alarm (Multiturn Limit Dis-
agreement) will be displayed because the setting disagrees with the value in the encoder.
If this alarm is displayed, use the following procedure to change the multiturn limit in the
encoder to the same value as the setting of Pn205.
Applicable Tools
The following table lists the tools that you can use to set the multiturn limit and the applicable
tool functions.
Operating Procedure
1.
Select
Setup - Multiturn Limit Setting
from the menu bar of the Main Window of the
S.
Default Setting
Not Default Setting
The multiturn data will always be 0 in the following cases. It is not necessary to reset the
absolute encoder in these cases.
•
When you use a single-turn absolute encoder
•
When the encoder is set to be used as a single-turn absolute encoder (Pn002 = n.
2
)
Absolute encoder-related alarms (A.810 and A.820) will not occur.
+
3
2,767
-
3
2,768
0
Number of
rotation
s
Multiturn data
Forward
Rever
s
e
0
Number of
rotation
s
Multiturn data
S
etting of Pn205
Forward
Rever
s
e
Information
Display
Name
Alarm Code Output
Meaning
A.CC0
Multiturn Limit Dis-
agreement
ALO1
ALO2
ALO3
Different multiturn limits are set in the
encoder and SERVOPACK.
ON (low) OFF (high) ON (low)
Tool
Function
Operating Procedure Reference
Panel Operator
Fn013
13.4.18 Multiturn Limit Setting after Multiturn Limit Dis-
agreement Alarm (Fn013)
Digital Operator Fn013
Σ
-7 Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
S
Setup - Multiturn Limit Setting