13.4 Utility Function (Fn
) Operations on the Panel Operator
13.4.18 Multiturn Limit Setting after Multiturn Limit Disagreement Alarm (Fn013)
13-24
13.4.18 Multiturn Limit Setting after Multiturn Limit Disagree-
ment Alarm (Fn013)
Refer to the following section for information on this utility function other than the procedure.
6.12.9 Multiturn Limit Disagreement Alarm (A.CC0)
13.4.19 Reset Option Module Configuration Error (Fn014)
Refer to the following section for information on this utility function other than the procedure.
12.2.6 Resetting Alarms Detected in Option Modules
4
Press the
MODE/SET
Key. The software version of
the encoder will be displayed.
Additional Information
If you press the
MODE/SET
Key again, a pre-pro-
grammed display will appear. The display will change
as follows:
0.0000
→
S.FFFF
→
F.FFFF.
5
Press the
DATA/SHIFT
Key for approximately one
second to return the display to
Fn012
.
Step
Panel Display after
Operation
Keys
Operation
MODE/SET
DATA/
MODE/SET
DATA/
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
2
Press the
UP
Key or
DOWN
Key to display
Fn013
.
3
Press the
DATA/SHIFT
Key for approximately one
second.
PGSEt
will be displayed.
4
Press the
MODE/SET
Key.
The value of the multiturn limit setting in the absolute
encoder will be made the same as the setting of
Pn205.
When unifying the values has been completed,
donE
will flash on the display for approximately one
second.
5
–
After displaying
donE
, the display will return to the
PGSEt
display.
6
Press the
DATA/SHIFT
Key for approximately one
second to return the display to
Fn013
.
7
To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON
again.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
MODE/SET
DATA/
MODE/SET
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
MODE/SET
DATA/