EZZ023536
14/16
Parameter List
No.
(Hex.)
Name
Description
Default Setting
(Range)
Ref.
SA: Crane Special Func
SA-01
(1AAA)
Expert
Load Share
Function
select
V/f
CL-V/f OLV CLV AOLV
Sets Load Share for the drive to master or slave. Set this
parameter to 0 to disable Load Share.
0: Disabled
1: Enabled. Sets Load Share for the drive to master.
2: Enabled. Sets Load Share for the drive to slave.
0
(0 to 2)
9
SA-02
(1AAB)
*1
Expert
Torque
Reference
Source
select
V/f CL-V/f OLV CLV AOLV
Selects how to imput the torque reference for the slave.
0: Control circuit terminal (analog input)
1: MEMOBUS communications
0
(0, 1)
9
SA-03
(1AAC)
Expert
Torque
Signal Select
V/f CL-V/f OLV CLV AOLV
Selects the type of torque signal that the slave receives from the
master.
0: Internal torque reference (U1-09)
1: Motor secondary current (U6-01)
0
(0, 1)
9
SA-04
(1AAD)
*2
Expert
Torque Limit
Select
V/f CL-V/f OLV CLV AOLV
Enables and disables the Torque Limit function for the slave.
Enable this function to use the torque reference value received
from the master as the torque limit of the slave.
0: Disabled
1: Enabled
0
(0, 1)
9
SA-05
(1AAE)
RUN
*2
Expert
Torque Limit
Bias
V/f CL-V/f OLV CLV AOLV
Sets the offset amount of the torque limit reference for the
slave.
10%
(-100% to 100%)
9
SA-06
(1AAF)
*2
Expert
Torque Filter
Time
V/f CL-V/f OLV CLV AOLV
Sets the primary delay time of the torque feedback value of the
slave. Reduce the setting value when the response of Load
Share control is slow. Increase the setting value when oscillation
occurs.
0.10 s
(0 s to 2.00 s)
9
SA-07
(1AB0)
*2
Expert
Load Share
Switch Time
V/f CL-V/f OLV CLV AOLV
Sets the time to switch Load Share for the slave. Increase the
setting value when oscillation occurs in the motor.
0.1 s
(0 s to 5.0 s)
10
SA-09
(1AB1)
*2
Expert
Load Share
on level1
V/f CL-V/f OLV CLV AOLV
Sets start level 1 for slave Load Share. Set this parameter to
0.0% to keep this function constantly enabled.
0.0%
(0.0% to 100.0%)
10
SA-10
(1AB2)
*2
Expert
Load Share
on level2
V/f CL-V/f OLV CLV AOLV
Sets start level 2 for slave Load Share. Set this parameter to
0.0% to keep this function constantly enabled.
0.0%
(0.0% to 100.0%)
11
SA-12
(1AB3)
*2
Expert
Load Share
function
stop select
V/f CL-V/f OLV CLV AOLV
Enables and disables Load Share when the slave stops.
0: Disabled
1: Enabled
0
(0, 1)
12
SA-20
(1AB4)
RUN
*2
Expert
Speed Gain
V/f CL-V/f OLV CLV AOLV
Sets the gain of the frequency reference that the slave receives
from the master.
1.000
(0.000 to
10.000)
12
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...