2.9 Change the Drive Enclosure Type
62
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
A - M10
×
20 hex bolts
B - M4
×
10 pan head screws
C - M10 plain washers
Figure 2.58 Install the Top Protective Cover
*1
Use the M10 x 20 hex bolts to fill the screw holes. Do not use them to attach the top protective cover.
■
Install the Conduit Bracket
•
Remove the drive hanging brackets before you install the kit.
•
Remove the knock-out holes on the UL Type 1 base before you install it to the drive.
Refer to
Remove the Knock-Out Holes on page 51
for more information.
1.
Use the included screws to assemble the stay brackets.
Tighten the screws to a correct tightening torque:
• 1.96 N
∙
m to 2.53 N
∙
m (17.35 lbf
∙
in to 22.39 lbf
∙
in)
A - Stay brackets
B - M5
×
12 pan head screws
Figure 2.59 Install the Stay Brackets
2.
Use the included screws to install the UL Type 1 base on the stay brackets.
Tighten the screws to a correct tightening torque:
• 1.96 N
∙
m to 2.53 N
∙
m (17.35 lbf
∙
in to 22.39 lbf
∙
in)
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Страница 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...