530
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
10.14 S: Crane Parameters
◆
S1: Brake Sequence
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
S1-01
(0680)
Brake Release
Frequency(FWD)
Sets the output frequency level at which to activate the brake release command during
forward run.
Note:
You must satisfy these three conditions to output the brake release command:
•
Output frequency after a soft start ≥ Brake release frequency
•
Output current > Brake release current
•
Torque reference ≥ Brake release torque (
A1-02 = 2, 3, or 4 [Control Method
Selection = OLV, CLV, or AOLV]
)
2.0 Hz
(0.0 - 20.0 Hz)
S1-02
(0681)
Brake Release
Frequency(REV)
Set the output frequency level at which to activate the brake release command during
reverse run.
Note:
You must satisfy these three conditions to output the brake release command:
•
Output frequency after a soft start ≥ Brake release frequency
•
Output current > Brake release current
•
Torque reference ≥ Brake release torque (
A1-02 = 2, 3, or 4 [Control Method
Selection = OLV, CLV, or AOLV]
)
2.0 Hz
(0.0 - 20.0 Hz)
S1-03
(0682)
Brake Delay Frequency
Sets frequency used until the brake is released.
Determined by A1-02
(0.0 - 400.0 Hz)
S1-04
(0683)
Brake Delay Time
Sets delay time before the brake is released.
Determined by A1-02
(0.00 - 10.00 s)
S1-05
(0684)
Brake Release Current
(FWD)
Sets the output current level at which to activate the brake release command during
forward run.
Note:
You must satisfy these three conditions to output the brake release command:
•
Output frequency after a soft start ≥ Brake release frequency
•
Output current > Brake release current
•
Torque reference ≥ Brake release torque (
A1-02 = 2, 3, or 4 [Control Method
Selection = OLV, CLV, or AOLV]
)
50%
(0 - 200%)
S1-06
(0685)
Brake Release Current
(REV)
Set the output current level at which to activate the brake release command during
reverse run.
Note:
You must satisfy these three conditions to output the brake release command:
•
Output frequency after a soft start ≥ Brake release frequency
•
Output current > Brake release current
•
Torque reference ≥ Brake release torque (
A1-02 = 2, 3, or 4 [Control Method
Selection = OLV, CLV, or AOLV]
)
30%
(0 - 200%)
S1-07
(0686)
Brake Release Torque
(FWD)
Sets the output torque level at which to activate the brake release command during
forward run.
Note:
You must satisfy these three conditions to output the brake release command:
•
Output frequency after a soft start ≥ Brake release frequency
•
Output current > Brake release current
•
Torque reference ≥ Brake release torque (
A1-02 = 2, 3, or 4 [Control Method
Selection = OLV, CLV, or AOLV]
)
100%
(0 - 200%)
S1-08
(0687)
Brake Release Torque
(REV)
Sets the output torque level at which to activate the brake release command during
reverse run.
Note:
You must satisfy these three conditions to output the brake release command:
•
Output frequency after a soft start ≥ Brake release frequency
•
Output current > Brake release current
•
Torque reference ≥ Brake release torque (
A1-02 = 2, 3, or 4 [Control Method
Selection = OLV, CLV, or AOLV]
)
0%
(0 - 200%)
S1-09
(0688)
Torque Compensation
(FWD)
Sets the torque compensation for forward operation.
Determined by A1-02
(-200 - +200%)
S1-10
(0689)
Torque Compensation
(REV)
Sets the amount of torque compensation for reverse run.
0%
(-200 - +200%)
S1-11
(068A)
Torque Compensation
Delay Time
Sets the length of time for torque compensation to go from 0% to 100%.
50 ms
(0 - 200 ms)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Содержание CR700
Страница 1: ......
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Страница 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...