![YASKAWA CIMR-RA Series Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/yaskawa/cimr-ra-series/cimr-ra-series_instruction-manual_907603085.webp)
5.3 Fault Detection
YASKAWA ELECTRIC
TOEP C710656 10B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
85
Tr
oub
le
sho
o
ti
n
g
5
Digital Operator
Display
Fault Name
Details
CPF06
EEPROM Memory
Data Error
Error in the data saved to EEPROM
Cause
Possible Solution
There is an error in EEPROM control circuit.
Turn off the power and check the connection between the control board and the regenerative unit.
If the problem continues, replace the control board or the entire regenerative unit. Contact
Yaskawa or a Yaskawa representative for instructions on replacing the control board.
The power supply was switched off while
parameters were being saved to the
regenerative unit.
Reinitialize the regenerative unit (A1-03 = 2220, 3330).
Digital Operator
Display
Fault Name
Details
CPF07
Terminal Board
Connection Error
There is a faulty connection in the removable terminal block.
CPF08
Cause
Possible Solution
There is a faulty connection between the
terminal board and the control board.
• Turn off the power and reconnect the terminal board.
• If the problem continues, replace the control board or the entire regenerative unit. Contact
Yaskawa or a Yaskawa representative for instructions on replacing the control board.
Digital Operator
Display
Fault Name
Details
CPF23
Control Board
Connection Error
Connection error between the control board and the regenerative unit
Cause
Possible Solution
Hardware is damaged.
Turn off the power and check the connection between the control board and the regenerative unit.
If the problem continues, replace the control board or the entire regenerative unit. Contact
Yaskawa or a Yaskawa representative for instructions on replacing the control board.
Digital Operator
Display
Fault Name
Details
CPF24
Unit Capacity Detect
Fault
The regenerative unit capacity cannot be detected correctly (regenerative unit capacity is checked
when the regenerative unit is powered up).
Cause
Possible Solution
Hardware is damaged.
If the problem continues, replace the control board or the entire regenerative unit. Contact
Yaskawa or a Yaskawa representative for instructions on replacing the control board.
Digital Operator
Display
Fault Name
Details
E5
MECHATROLINK
Watchdog Timer Error
The watchdog timed out.
Cause
Possible Solution
Data has not been received from the PLC.
Execute DISCONNECT or ALM_CLR, then issue a CONNECT command or SYNC_SET
command and proceed to phase 3. Refer to the MECHATROLINK Option Technical Manual for
more details on troubleshooting.
Digital Operator
Display
Fault Name
Details
EF0
Option Card External
Fault
An external fault condition is present.
Cause
Possible Solution
An external fault was received from the PLC
and F6-03 is set to a value other than 3.
• Remove the cause of the external fault.
• Remove the external fault input from the PLC.
Problem with the PLC program
Check the PLC program and correct problems.
Digital Operator
Display
Fault Name
Details
EF1
External Fault
(input terminal S1)
External fault at multi-function input terminal S1.
EF2
External Fault
(input terminal S2)
External fault at multi-function input terminal S2.
EF3
External Fault
(input terminal S3)
External fault at multi-function input terminal S3.
EF4
External Fault
(input terminal S4)
External fault at multi-function input terminal S4.
EF5
External Fault
(input terminal S5)
External fault at multi-function input terminal S5.
TOEP_C710656_10B_1_0.book 85 ページ 2015年1月8日 木曜日 午後8時55分