B.3 Defaults by Unit Model
B.3 Defaults by Unit Model
The following tables show parameters and default settings that change with o2-04 (Unit Model Selection).
Table B.1 200 V Class Model Default Settings by Regenerative Unit Model Selection
Table B.2 400 V Class Model Default Settings by Regenerative Unit Model Selection
No.
Name
Unit
Default Settings
Model
– 2A03P5 2A0005 2A0007 2A0010 2A0014 2A0017 2A0020 2A0028 2A0035 2A0053 2A0073 2A0105
o2-04
Unit Model
Selection
Hex
68
6A
6B
6D
6E
6F
70
72
73
75
76
78
C7-14
Bias Voltage at
Operation Start
V
2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0
C7-15
Voltage Hysteresis
Width at Operation
Start/Stop
V
3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
L2-02
Momentary Power
Loss Ride-Thru
Time
s
1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0
L2-05
Undervoltage
Detection Level
(Uv)
V
190
190
190
190
190
190
190
190
190
190
190
190
L2-21
AUv Detection
Level
V
150
150
150
150
150
150
150
150
150
150
150
150
L8-02
Overheat Alarm
Level
°
C
85
105
110
115
115
120
120
120
110
115
110
120
L8-66
Power Supply Fault
Detection Voltage
Level
%
50
50
50
50
50
50
50
50
50
50
50
50
L8-35
Installation Method
Selection
–
2
2
2
2
2
2
2
2
0
0
0
0
No.
Name
Unit
Default Settings
Model
–
4A03P5 4A0005 4A0007 4A0010 4A0014 4A0017 4A0020 4A0028
o2-04
Unit Model Selection
Hex
97
99
9A
9C
9D
9E
9F
A1
C7-14 Bias Voltage at Operation Start
V
4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0
C7-15
Voltage Hysteresis Width at Operation
Start/Stop
V
6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0
L2-02 Momentary Power Loss Ride-Thru Time
s
1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.0
L2-05 Undervoltage Detection Level (Uv)
V
380
380
380
380
380
380
380
380
L2-21 AUv Detection Level
V
300
300
300
300
300
300
300
300
L8-02 Overheat Alarm Level
°
C
80
85
100
95
110
105
115
110
L8-66
Power Supply Fault Detection Voltage
Level
%
50
50
50
50
50
50
50
50
L8-35 Installation Method Selection
–
2
2
2
2
2
2
2
2
No.
Name
Unit
Default Settings
Model
–
4A0035 4A0043 4A0053 4A0073 4A0105 4A0150 4A0210 4A0300
o2-04
Unit Model Selection
Hex
A2
A3
A4
A5
A7
A9
AC
AE
C7-14
Bias Voltage at Operation Start
V
4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0
C7-15
Voltage Hysteresis Width at Operation
Start/Stop
V
6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0
L2-02
Momentary Power Loss Ride-Thru Time
s
2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0
L2-05
Undervoltage Detection Level (Uv)
V
380
380
380
380
380
380
380
380
L2-21
AUv Detection Level
V
300
300
300
300
300
300
300
300
L8-02
Overheat Alarm Level
°
C
110
115
115
110
110
110
140
140
L8-66
Power Supply Fault Detection Voltage
Level
%
50
50
50
50
50
50
50
50
L8-35
Installation Method Selection
–
0
0
0
0
0
0
0
0