background image

YASKAWA Europe GmbH

In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture 
thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations.  Therefore, be sure 
to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications and improvements.

©

 2010 YASKAWA Europe GmbH. All rights reserved.

EUROPEAN HEADQUARTERS

YASKAWA EUROPE GmbH

Am Kronberger Hang 2, 65824 Schwalbach, Germany

Phone: +49 (0)6196 569 300     Fax: +49 (0)6196 569 398

E-mail: [email protected]    Internet: http://www.yaskawa.eu.com

YASKAWA ENGINEERING EUROPE GmbH

Am Kronberger Hang 2, 65824 Schwalbach, Germany

Phone: +49 (0)6196 569 520     Fax: +49 (0)6196 569 598

E-mail: [email protected]

U.S.A.

YASKAWA AMERICA, INC.

2121 Norman Drive South, Waukegan, IL 60085, U.S.A.

Phone: +1 847 887 7000     Fax: +1 847 887 7170

Internet: http://www.yaskawa.com

JAPAN

YASKAWA ELECTRIC CORPORATION

New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo, 105-0022, Japan 

Phone: +81 (0)3 5402 4511     Fax: +81 (0)3 5402 4580

Internet: http://www.yaskawa.co.jp

Published in Germany   

May

 2010  

10-5

MANUAL NO.  TOEP C710606 27A

07-12_YEU

Quick Start Guide

YASKAWA AC Drive J1000

Compact V/f Control Drive

2

Содержание CIMR-JCBA0001

Страница 1: ...put 0 1 to 5 5 kW 200 V Class Single Phase Input 0 1 to 2 2 kW 400 V Class Three Phase Input 0 2 to 5 5 kW MANUAL NO TOEP C710606 27A Type CIMR JC To properly use the product read this manual thorough...

Страница 2: ...n permission of YASKAWA No patent lia bility is assumed with respect to the use of the information contained herein Moreover because YASKAWA is constantly striving to improve its high quality products...

Страница 3: ...k Start Guide J1000 Quick Start Guide ENGLISH 1 Safety Instructions and General Warnings 4 2 Mechanical Installation 9 3 Electrical Installation 11 4 Keypad Operation 18 5 Start Up 20 6 Parameter Tabl...

Страница 4: ...provided to the end user YASKAWA offers an express warranty only as to the quality of its products in conforming to standards and speci fications published in the manual NO OTHER WARRANTY EXPRESS OR I...

Страница 5: ...uld result in death or serious injury Maintenance inspection and replacement of parts must be performed only by authorized personnel familiar with installation adjustment and maintenance of AC drives...

Страница 6: ...ply could result in death or serious injury by fire Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power Do not use improper combustible ma...

Страница 7: ...esult in further damage to the equipment Do not connect or operate any equipment with visible damage or missing parts Install adequate branch circuit short circuit protection per applicable codes Fail...

Страница 8: ...2 and overvoltage category 3 in accordance with IEC664 Ground the neutral point of the main power supply for 400 V Class drives Precautions for UL cUL Standards Compliance This drive is tested in acc...

Страница 9: ...Environment Conditions Installation Area Indoors Ambient Temperature 10 qC to 50 qC When using an enclosure panel install a cooling fan or air conditioner in the area to ensure that the air temperatur...

Страница 10: ...03 68 128 118 56 118 5 38 5 109 5 M4 1 0 BA0006 108 128 137 5 96 118 5 58 129 M4 1 7 BA0010 108 128 154 96 118 5 58 145 5 M4 1 8 2A0001 68 128 76 56 118 5 6 5 67 5 M4 0 6 2A0002 68 128 76 56 118 5 6 5...

Страница 11: ...er Fuses Main Switch Forward Stop Reverse Stop External Fault Fault Reset Multi speed 1 Multi function digital inputs default setting Link Thermal relay Braking resistor option J1000 Ground Multi func...

Страница 12: ...5 M3 5 BA0002 FS23638 10 07 2 5 M3 5 M3 5 M3 5 BA0003 FS23638 10 07 2 5 M3 5 M3 5 M3 5 BA0006 FS23638 20 07 2 5 M4 M4 M4 BA0010 FS23638 20 07 4 M4 M4 M4 2A0001 FS23637 8 07 2 5 M3 5 M3 5 M3 5 2A0002...

Страница 13: ...se Type Manufacturer Ferraz Fuse Ampere Rating A Fuse Type Manufacturer Bussmann 500 Vac 200 kAIR Fuse Ampere Rating A Single Phase 200 V Class BA0001 A6T6 6 FWH 25A14F 25 BA0002 A6T10 10 FWH 25A14F 2...

Страница 14: ...drives smaller than 1 kW for compliance with the EN61000 3 2 Refer to the instruction manual or contact your supplier for details EMC Standards Compliant Wiring of Single and Three Phase Units Termina...

Страница 15: ...A Wiring the Main Circuit Output Consider the following precautions for the output circuit wiring Do not connect any other load than a 3 phase motor to the drives output Never connect a power source t...

Страница 16: ...rnal control power supply use a UL Listed Class 2 power supply Use twisted pair or shielded twisted pair cables for control circuits to prevent operating faults Ground the cable shields with the maxim...

Страница 17: ...o 5 Photocoupler inputs 24 Vdc 8 mA Note Drive preset to sinking mode NPN When using source mode set DIP switch S3 to SOURCE and use an external 24 Vdc 10 power supply SC Multi function input common S...

Страница 18: ...was active during power up Up Arrow Key Scrolls up to select parameter numbers setting values etc Down Arrow Key Scrolls down to select parameter numbers setting values etc STOP Key Stops the drive EN...

Страница 19: ...Output Frequency Output Current Output Voltage Monitor Display Verify Menu Setup Mode Parameter Setting Mode DRV LED is on A Run command will start the motor The Monitor Displays are used to read out...

Страница 20: ...tion parameters if necessary Final check the operation and verify the settings Drive is ready to run the application Intstall and wire the drive as explained Turn the power on Initialize the drive if...

Страница 21: ...that the drive is in the REMOTE mode Mode Heavy Duty Ratings HD Normal Duty Rating ND C6 01 0 1 Application Applications with a constant torque like extruders conveyors and cranes High overload capabi...

Страница 22: ...r the analog input Select the input sig nal level in parameter H3 01 NOTICE If the input signal level of input A1 is switched between voltage and current make sure that DIP switch S1 is in the correct...

Страница 23: ...be activated in the C2 parameters for softer accel decel start and end Test Run Perform the following steps to start up the machine after all parameter settings have been done 1 Run the motor without...

Страница 24: ...raking Current Sets the DC Injection Braking cur rent as a percentage of the drive rated current b2 03 DC Inj Braking Time DC Excitation Time at Start Sets the time of DC Injection Brak ing at start i...

Страница 25: ...oad Current Magnetizing current in Ampere E2 05 Motor Line to Line Resistance Sets the phase to phase motor resistance in ohms Digital Input Settings H1 01 to H1 05 DI S1 to S5 Function Selection Sele...

Страница 26: ...z U1 03 Output Current A U1 06 Output Voltage Reference Vac U1 07 DC Bus Voltage Vdc U1 10 Input Terminal Status Par Name Description 1 Digital input 1 terminal S1 enabled 1 Digital input 2 terminal S...

Страница 27: ...base block function is assigned to one of the digital inputs and the input is off The drive does not accept Run commands ControlCircuit Fault There is a problem in the drive s control circuit Cannot...

Страница 28: ...he load is too heavy The drive capacity is too small Too much torque at low speed DC Overvoltage DC bus voltage rose too high The deceleration time is too short Stall prevention is disabled Braking ch...

Страница 29: ...ing of other input functions were set alone Input functions that are not allowed to be used simultaneously have been set Fix any incorrect settings Refer to the instruction manual for more details oPE...

Страница 30: ...75qC and closed loop con nectors or CSA certified ring connectors sized for the selected wire gauge to maintain proper clearances when wiring the drive Use the correct crimp tool to install connector...

Страница 31: ...3 M5 R5 5 5 2 0 to 2 5 17 7 to 22 1 M6 R5 5 6 4 0 to 5 0 35 4 to 44 3 M8 R5 5 8 9 0 to 11 0 79 7 to 97 4 8 8 M4 8 4 1 2 to 1 5 10 6 to 13 3 M5 R8 5 2 0 to 2 5 17 7 to 22 1 M6 R8 6 4 0 to 5 0 35 4 to 4...

Страница 32: ...V class drives motor over load protection Drive Motor Overload Protection Set parameter E2 01 motor rated current to the appropriate value to enable motor overload protection The internal motor overlo...

Страница 33: ...ne motor for simultaneous operation Enable the motor overload protection L1 01 1 2 or 3 when connecting the drive to a sin gle motor unless there is another means of preventing motor thermal overload...

Страница 34: ...ameter will set the allowed operation time before the OL1 fault will occur when the drive is running at 60 Hz and 150 of the motor s full load amp rating E2 01 Adjusting the value of L1 02 can shift t...

Страница 35: ...e back cover Date of Publication Rev No Section Revised Contents January 2008 First edition June 2009 Back cover Revision Address May 2010 Chapter 8 Instructions for UL and cUL MANUAL NO TOEP C710606...

Страница 36: ...DQUARTERS YASKAWA EUROPE GmbH Am Kronberger Hang 2 65824 Schwalbach Germany Phone 49 0 6196 569 300 Fax 49 0 6196 569 398 E mail info yaskawa eu com Internet http www yaskawa eu com YASKAWA ENGINEERIN...

Отзывы: