VAN-V17001E<1>, Replacing A1000 crane with CR700
34/44
4-3.
Drive Installation Attachment to Match Mounting Dimensions
Dimensions for the open type enclosure drives and enclosed wall-mounted type drives are shown below.
CR700 has a larger depth than A1000.
The attachment makes it possible to mount CR700 using the same mounting holes as A1000.
First mount the installation attachment to the holes that A1000 was using, and then mount CR700 to the
attachment.
The installation depth increases due to the size of the attachment. The number in parenthesis indicates
the dimension when using the attachments.
Open Type Enclosure (IP20) Table lists the Heavy Duty (HD) rating.
Voltage
Class
Capacity
(kW)
Dimensions (mm)
Drive Installation Attachment
Code No.
A1000
CR700
W
H
D
W
H
D
Normal installation External heatsink
Three-
phase
200 V
class
0.4
140
260
147
140
260
176
(189
䠅
100-206-987
Contact
Yaskawa.
0.75
1.1
1.5
2.2
3
164
211
(224)
3.7
5.5
167
7.5
11
180
300
187
180
300
202
(215)
100-206-988
15
220
350
197
220
350
227
Contact
Yaskawa.
18.5
220
365
197
220
350
227
22
250
400
258
240
400
280
30
275
450
255
450
280
37
325
550
283
264
543
335
45
55
450
705
330
312
700
420
75
90
500
800
350
440
800
472
Three-
phase
400 V
class
0.4
140
260
147
140
260
176
(189
䠅
100-206-987
Contact
Yaskawa.
0.75
1.5
2.2
164
211
(224)
3
3.7
5.5
167
7.5
11
180
300
180
300
202
(215)
100-206-988
15
187
18.5
220
350
197
220
350
227
Contact
Yaskawa.
22
250
400
258
220
350
246
30
275
450
240
400
280
37
325
510
258
255
450
280
45
55
325
550
283
264
543
335
75
90
450
705
330
312
700
420
110
500
800
350
132
160
440
800
472
185
500
950
370
220
670
1140
510
1136
480
315