The
pulse duration
tells for what time the output is set when the para-
meterized comparison criterion is reached. The
pulse duration
can be
set in steps of 2.048ms between 0 and 522.24ms. If the
pulse dura-
tion
= 0, the output is set active until the comparison condition is not
longer fulfilled.
4.4 Counter - Functions
You may count forward and backwards and choose between the fol-
lowing counter functions:
n
Count endless, e.g. distance measuring with incremental encoder
n
Count once, e.g. count to a maximum limit
n
Count periodic, e.g. count with repeated counter process
In the operating modes "Count once" and "Count periodic" you may
define a counter range as start and end value via the parameteriza-
tion. For every counter additional parameterizable functions are avail-
able like gate function, comparison, hysteresis and process interrupt.
Via the parameterization you have the opportunity to define a main
counting direction for every counter. If "none" is chosen, the complete
counting range is available:
Limits
Valid value range
Lower count limit
-2 147 483 648 (-2
31
)
Upper count limit
+2 147 483 647 (2
31
-1)
Main counting direction forward
Upper restriction of the count range. The counter counts 0 res.
load
value
in positive direction until the parameterized
end value
-1 and
jumps then back to the load value with the next following encoder
pulse.
Main counting direction backwards
Lower restriction of the count range. The counter counts from the par-
ameterized start- res.
load value
in negative direction to the parame-
terized
end value
+1 and jumps then back to the start value with the
next following encoder pulse.
If the HW gate is enabled, only the HW gate may be influenced by the
gate functions. An opening and closing of the SW gate only interrupts
the count process.
Abort count process
The count process starts after closing and restart of the gate begin-
ning with the
load value
.
Interrupt count process
The count process continuous after closing and restart of the gate
beginning with the last recent counter value.
PULSE_I Pulse (dura-
tion)
Overview
Main counting direction
Gate function abort/
interrupt
VIPA System SLIO FM 050
Deployment
Counter - Functions
HB300 | FM | 050-1BA00 | GB | 15-11
48