GENERAL SAFETY INSTRUCTIONS

1) WORK AREA
a) Do not operate pump in explosive atmospheres, such as in the presence of flammable liquids, gases

or dust. 

Engine may create sparks which may ignite the dust or fumes.

b) Never run engine in an enclosed area. Exhaust gases contain deadly, poisonous carbon monoxide,

which has no odor or taste. 

Exposure may cause loss of consciousness and may lead to death.

c) Keep by-standers, children and visitors away while installing pump. 

Distractions can result in mistakes.

d) Keep the engine at least 1 meter (3 feet) away from buildings and other equipment during

operation. Do not place flammable objects close to the engine. 

Procedure should be followed to prevent

fire hazards and to provide adequate ventilation.

2) PERSONAL SAFETY
a) Stay alert, watch what you are doing and use common sense when operating this pump. Do not

attempt to use pump while tired or under the influence of drugs, alcohol or medications. 

A moment of

inattention while operating power tools may result in serious personal injury.

b) Dress appropriately. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing

and gloves away from moving parts.

Loose clothes, jewelry or long hair can be caught in moving parts.

c) Do not overreach. Keep proper footing and balance at all times. 

Proper footing and balance enables better

control of the pump in unexpected situations.

d) Use safety equipment. 

Always wear eye protection. Dust mask, non-skid safety shoes and hard hat must be

used for appropriate conditions.

3) PUMP USE AND CARE
a) Store idle pump out of reach of children and other untrained persons. 

Pumps are dangerous in the hands

of untrained users. 

b) Maintain pump. Keep hoses in proper operating condition. 

Properly maintained pumps are less likely to

malfunction and cause injury.

c) Check for misalignment or binding of moving parts, breakage of parts and any other condition that

may affect the pumps operation. 

If damaged, have the pump serviced before using. Accidents can be caused

by poorly maintained pumps. 

d) Always shut off the engine, allow the engine to cool and remove the spark plug before performing any

maintenance. 

Such preventative measures reduce the risk of starting the pump accidentally.

e) Keep handles dry and clean; free from oil and grease.  

Allows for better control of the pump.

4) SERVICE
a) Pump service must be performed only by qualified repair personnel. 

Service or maintenance performed by

unqualified repair personnel could result in injury.

b) When servicing a pump, use only identical replacement parts. Follow instructions in the Maintenance

Section of this manual. 

Use of unauthorized parts or failure to follow maintenance instructions may create a

risk of injury and may void your warranty.

Содержание YW65PHP

Страница 1: ...all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Instruction Manual 6 5H...

Страница 2: ...PECIFICATIONS KNOW YOUR PRODUCT PACK CONTENTS DESCRIPTION OF SYMBOLS GENERAL SAFETY INSTRUCTIONS ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS SET UP INSTALLATION OPERATION MAINTENANCE SPARE PARTS TROUBLES...

Страница 3: ...se with a confirmed cash register receipt SHOULD YOU HAVE ANY QUESTIONS PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY OR REPAIR PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE Australia 1800 069 486 New...

Страница 4: ...es emptying rainwater tanks pools and spas emptying garden ponds and transferring water for domestic agricultural irrigation Motor Power 6 5HP Engine Type 4 Stroke air cooled Fuel Type Unleaded petrol...

Страница 5: ...g Cap 2 Fuel Cap 3 Fuel Tank 4 Motor Housing 5 Recoil Starter 6 Throttle Lever 7 Fuel Lever 8 Choke Lever 9 Air Filter 10 Exhaust 4 1 3 2 5 10 4 6 7 8 9 WARNING THIS PRODUCT IS NOT SUITABLE FOR USE WI...

Страница 6: ...W YOUR PRODUCT cont KNOW YOUR PRODUCT cont 5 12 18 11 13 14 15 16 17 11 Discharge Outlet 12 Pump Housing 13 Suction Inlet 14 Drain Screw 15 Oil Fill Plug 16 Low Oil Sensor 17 On Off Switch 18 Spark Pl...

Страница 7: ...ction Hose 20 25 4mm 1 Outlet Cap 21 25 4mm 1 Collar 22 25 4mm 1 Hose Adaptor 23 25 4mm 1 Hose Clamp 24 25 4mm 1 O ring 25 40mm 11 2 Inlet Outlet Cap 26 40mm 11 2 Collar 27 40mm 11 2 Hose Adaptor 28 4...

Страница 8: ...11 2 Hose Clamps 3 x 40mm 11 2 O rings 1 x Filter 1 x Spark Plug Spanner 1 x Instruction Manual DESCRIPTION OF SYMBOLS Hp Horse power Hz Hertz Alternating current W Watts min Revolutions or no No load...

Страница 9: ...ooting and balance at all times Proper footing and balance enables better control of the pump in unexpected situations d Use safety equipment Always wear eye protection Dust mask non skid safety shoes...

Страница 10: ...ool before transporting or storing it indoors The muffler becomes very hot during operation and remains hot for a while after stopping the engine Exhaust may contain chemicals that may cause cancer or...

Страница 11: ...ne to prevent the pipe from collapsing due to pressure from suction Caution All connections require being air tight failure to do so cause result in an air leak which can prevent the pump from priming...

Страница 12: ...utlet caps onto the 2 of the 3 discharge outlets 11 that are not going to be used Fig 7 Note Multiple outlets can be used to pump water simultaneously but this will result in lower pressure and flow r...

Страница 13: ...or issue for engine reliability of operation WARNING Do not over fill the fuel tank WARNING Do not smoke while re fueling 1 Use unleaded petrol with a minimum of Octane 91 2 Use clean fresh fuel purch...

Страница 14: ...rk plugs 18 for engines are the same 1 Use only the spark plug 18 that is recommended for this high pressure petrol pump Champion L90C 2 Check the length of the thread because if the thread is to long...

Страница 15: ...e at the outlet Adjusting the Throttle The throttle is used to regulate the RPM of the engine which also controls the water flow out of the discharge outlet 1 To increase the speed of the engine and w...

Страница 16: ...thetic oils 5W 30 multi viscosity is used for temperatures 5 to 5 C 1 Place the high pressure pump on a level surface 2 Clean around the oil fill plug 15 3 Remove the oil fill plug 15 from both the le...

Страница 17: ...otected from bad weather conditions If the pump is not going to be used for a long period of time it is advisable to rinse with water Ensure the pump is completely dry before storing 16 Fig 19 topupif...

Страница 18: ...tact your local Bunnings Special Orders Desk to order the required spare parts Most common spare parts listed below Spare Part Part No Air Filter SPYW65PHP 08019 Fuel Tank Filter SPYW65PHP 1103 Fuel T...

Страница 19: ...adjusted incorrectly Move choke lever to CLOSED unless engine is warm Refer to engine operating instructions Unit starts but runs and performs poorly Air Filter clogged Check clean or replace filter a...

Отзывы: