29
F - CROUZET – XD-10 Controller
The first LCD display to appear is the Input/Output image table and the Real Time clock.
An i/o no. indicates inactive i/o while a darkened i/o no. indicates an active i/o.
- PLC inputs display.
- PLC outputs display.
- Time display.
- PLC run indication.(rotating)
- PLC operation keys
Updating time & date.
1. press
OK
key.
2. Move to
MISCELLANEOUS
line by pressing
[ -
]
key
twice
and press
[ OK ]
key.
3. Move to
CLOCK
line by pressing
[ - ]
key and press the
[ OK ]
key.
4. On
DATE/HOUR SETUP
press the
[ OK ]
key and move to the required field using
[ -
]
/
[ +
]
keys.
When the required field blinking and darkened , Press
the
[ OK ]
key - the field is
blinking but not darkened, in this state use the
[ -
]/ [ +
]
keys to change the field
value.
When done, press the
[ OK ]
key to enter the new value - the field is blinking and
darkened again.
5. Move to other fields or exit to the main screen by pressing the
[ ESC]
key until the
main Screen appears.
PARAMETERS CHANGE/UPDATE PROCEDURE.
When a desire parameter screen displayed , it's value is darkened with black dotes.
(In case of parameter with two fields like DP ON/OFF TM
use the
[ -
]/ [ +
]
keys to
move between them
.
)
To change a value –
A. Press the
[ OK ]
key > the value is blinking without the darkened dots.
B. Change the value by pressing the
[ -
]/ [ +
]
keys.
(Note that you can hold the
[ -
]/ [ +
]
keys for fast change or to click them for
slow change.)
C. When done press the
[ OK ]
key to enter the new value > the new value is
darkened with black dotes again.
D. Move to the next parameter by pressing the
[ A ]
key again or exit by pressing
the
[ESC
] Key.