DC Inverter U-match Series Cassette Type Unit
53
NOTE:
Check the above items and adopt the corresponding corrective
measures. If the air conditioner continues to function poorly, please stop the air
conditioner immediately and contact
YAMATO
’s authorized local service center. Ask our
professional service staff to check and repair the unit.
5.2 Error Code
WARNING!
(1) If abnormal things (for example, awful smell) occur, please stop the unit
immediately and disconnect power. Then contact
YAMATO
’s authorized service
center. If the unit continues to run in abnormal situations, it may get damaged
and cause electric shock or fire hazard.
(2) Do not repair the air conditioner by yourself. Improper maintenance will cause
electric shock or fire hazard. Please contact
YAMATO
’s authorized service center
and send for professional service staff to repair.
If the display panel or wired controller displays an error code, please refer to
the error code meaning stated in the following table.
Error
code
Error
Error
code
Error
A1
Outdoor fan IPM module
protection
LE
Compressor overspeed
Ac
Outdoor fan startup failure
LF
Power protection
Ad
Outdoor fan Phase-loss
protection
LP
IDU and ODU unmatched
AE
Outdoor fan current detection
circuit error
oE
ODU error, for specific error
please see the status of ODU
main board indicator
AJ
Outdoor fan out-of-step
protection
P0
Driver reset protection
C0
Wired controller and indoor unit
communication failure
P5
Compressor phase over-current
protection
C1
Indoor ambient temperature
sensor error
P6
Master control and driver
communication error
C2
Evaporator temperature sensor
error
P7
Module temperature sensor
circuit failure
C3
Condenser temperature sensor
error
P8
Driver module temperature
protection
C4
ODU jumper cap error
P9
AC contractor protection