![Yamato WA500 Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/yamato/wa500/wa500_instruction-manual_905421041.webp)
-38-
Maintenance
Cleaning Still
Removal and setting the still
(1) Turn
“OFF” the circuit bleaker.
(2) Close the faucet.
(3) Make sure if the boiler cools down enough (about 30 min. later) after the breaker is turned
“OFF”.
Open the left door of this unit and the cock to drain boiler water.
(4) Remove both hose connected to the
①
boiler and
②
condenser respectively. Cap nut is used in the
joint. Be careful not to lose or damage the inside packing at removal.
(5) Take off the butterfly nut from
③
heater cover.
(6) Take off
③
heater cover and remove all leads from heaters and overheat detectors.
(7) Take off
④
connecting screws, separate
②
condenser and
①
boiler. Be careful not to lose or
damage
⑤
packing.
(8) Remove
①
boiler first from the body. Take off the
⑨
fixed screw by cross driver. Pull
①
boiler
forward to remove from the body. Be careful about the hose joint at the removal.
(9) Hold
②
condenser and loosen
⑥
metal fixture in the middle of
②
condenser by cross driver. Be
careful not to drop the heavy (about 9kg) boiler.
(10)Fit
①
boiler and
②
condenser in the reverse procedure. Make sure the positions to cennect
securely each hose and lead.
⑧
②
③
①
⑤
④
⑥
⑦
⑨
WA710/730 only