26
VG3511-8F
6. Adjustments
6.6 Using timing gauge
6.5 Distance between needle and looper
The distance “L” between the looper tip and the center of
the right needle depends on the needle distance when the
needles are at the lowest points and the looper ① is at the
extreme right.
See Table 5 and loosen the screw ② of the looper holder
to adjust the distance.
The timing gauge (No. 95220) makes it possible to adjust
the distance easily.
The gauge is an extra part. Place an order with our agents
or directly with us, if needed.
Fig. 6-15
Fig. 6-14
Fig. 6-13
A timing gauge has the marks (
A, B, C, D, E
) for each
needle distance.
Move the looper at the extreme right. Keep fitting the
right needle into the groove “V” corresponding needle
distance, and fit the looper tip to the gauge.
Then, tighten the screw ② securely.
6.0 ㎜
Table 5
AE
C
B
needles
①
D
The distance between the center of the needle bar and
the looper ① tip is 6.0 mm even if the needle distance
changes.
①
②
L
SUPPLEMENT
needle distance
(mark)
gauge mark
looper's
distance "L"
3.2 ㎜ (32)
A
4.4 ㎜
4.0 〃 (40)
B
4.0 〃
4.8 〃 (48)
C
3.6 〃
5.6 〃 (56)
D
3.2 〃
6.4 〃 (64)
E
2.8 〃
Содержание VG3511-8F
Страница 2: ......
Страница 8: ...iv Safety instructions Rotating direction symbol ...
Страница 49: ......
Страница 50: ......
Страница 51: ......