21
VG3511-8F
6
. Adjustments
Before operating, ALWAYS turn the power switch OFF and check that the machine has already stopped.
6.1 Needle thread tension
Fig. 6-1
Fig. 6-2
Needle thread take-up
Procedure:
(1) Loosen the screws ② and ③ .
(2) Tighten the screws ② and ③ securely.
As standard, set the part “a” horizontally, and make the
distance between the screw ② the needle thread take-
up ① tip to 34.5 ㎜ when the needle bar is at the highest
point.
Needle thread eyelet
If the above mentioned adjustments are not enough or
want to make adjustment for each needle thread, perform
the following steps.
Procedure:
(1) Loosen the screws ⑤ .
(2) Tighten the screws ⑤ securely.
As standard, make the distance between the needle thread
eyelet holder ⑥ and each eye of the needle thread eyelet
④ as below.
Left needle: 25 ㎜
Middle needle: 17.5 ㎜
Right needle: 10 ㎜
Adjusting all eyelets together:
(1) Loosen the screw ⑦ of the SP device.
(2) Tighten the screw ⑦ securely.
As standard, set the SP device at the highest point.
● To tighten the needle thread, move the needle
thread take-up ① in the direction T.
● To loosen the needle thread, move the needle
thread take-up ① in the direction L.
● To tighten the needle thread, move each eyelet ④
in the direction T.
● To loosen the needle thread, move each eleyet ④
in the direction L.
● To tighten the needle thread, move the SP device
⑧ in the direction T.
● To loosen the needle thread, move the SP device
⑧ in the direction L.
34.5 ㎜
①
②
③
a
T
L
25 ㎜
17.5 ㎜
10 ㎜
④
⑤
⑥
T
L
Fig. 6-3
⑦
⑧
T
L