Checkweighing Function
The checkweighing function uses a lower limit and upper limit to establish an acceptable weight range
for portioning, quality control and filling while displaying the weight loaded on the platform. The bar
chart gives a graphical representation of the status of the loaded weight in relationship to the upper
and lower limits for quick reference. Up to 99 different setups can be stored for later recall. Available
options include a flashing indication to announce an acceptable, unacceptable, under, or over weight
condition.
Enable
1. To enable the checkweighing function, press the
and
keys at
the same time. The yellow tabs on these keys are reminders of how
to enter user setup mode. You are now in user setup mode with pa-
rameter 01 displayed.
2. Use the
and
keys to change the parameter value to 002. The
down and up arrows next to these keys indicate that they decrease
and increase, respectively, the displayed value.
3. To store any changes made to this parameter and to advance to the
next parameter, press the
key. The right arrow next to this key
indicates that it advances the display to the next parameter.
4. If you wish to set a flashing weight reading, advance to parameter 07.
000 disables the flashing feature.
001 flashes when a stable weight under the acceptable weight
range is loaded.
002 flashes when a stable weight in the acceptable weight range is
loaded.
003 flashes when a stable weight over the acceptable weight range is loaded.
004 flashes when a stable weight outside the acceptable weight range is loaded.
Press the
key to save any changes and advance to the next parameter.
5. When all the parameters in user setup mode are properly configured, press the
key for about
three seconds to turn the scale off. Press the
to turn the scale on. The checkweighing function
is now enabled.